1/0 1C Type P Power Cable, 2KV
Cut to length - sold by the foot. Enter the desired footage in the QTY box.
Minimum 25' to maximum 1000'. Please call for longer put ups.
Applications:
Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Type P cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored & sheathed). The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). This product may be manufactured in an unarmored or armored and sheathed version.
Features/Ratings:
- Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
- High strand count conductors provide superior flexibility
- Higher allowable conductor operating temperature results in increased ampacity
- Cold bend/ cold impact of -40°/ -35°C in accordance with CSA 22.2 No. 0.3
- Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A
- Unarmored cables suitable for Class 1, Division 2 and Zone 2 hazardous locations offshore
Conductor:
Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.
Insulation/Jacket:
Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580
Approvals:
- IEEE 1580 and IEEE 45- Marine Shipboard Cable
- UL 1309- Marine Shipboard Cable Type X110
- CSA 22.2 No. 245- Marine Shipboard Cable Type X110
- CSA 22.2 No. 230 as Type TC (#4/0 AWG and larger)
- Det Norske Veritas (DNV)
- American Bureau of Shipping (ABS)
- Transport Canada Approved AMS400-20-2
- Transport Canada 8700-20-2
- Lloyd’s Register of Shipping (LRS)
- United States Coast Guard-46CFR
Specifications*:
Size: 1/0
mm2: 56.3
Number of Conductors: 1
Nominal Diameter: 0.540
Current AMPS: Free Air 125°C = 319, 110°C = 243, 100°C = 227, 95°C = 223
Weight: 0.430 lbs per ft
This information is provided for reference only. This information is not intended to replace the information in the appropriate and applicable standard or code. †Ampacity based on 45°C ambient temperature: 95°C values based on ABS MODU Rules Table 6 - 1OO°C values based on IEEE-45 - 11O°C values based on API 14F. *125°C ampacities based on 45°C ambient in free air.
There are no reviews for this product.