The new residential Level 2 EV charger uses SmartAmp load management to vary charging output with available household electrical capacity, potentially reducing the need for a panel or service upgrade on qualifying projects.
Key takeaways
- Schneider Electric announced Schneider Charge availability in Canada on August 25, 2026.
- SmartAmp uses current transformers to monitor household load and can reduce or restore EV charging output as available capacity changes.
- The hardwired charger range is rated up to 11.5 kW and 48 A, with NACS and J1772 versions listed for Canada.
- Load management does not remove the need for site assessment, professional installation or approval by the local authority having jurisdiction.
Canadian launch confirmed
Schneider Electric announced the Canadian launch of Schneider Charge on August 25, 2026. The product is a residential Level 2 AC EV charger positioned for homes where the additional continuous load of EV charging could otherwise trigger a larger electrical upgrade.
The Canadian rollout is part of a broader United States and Canada introduction announced the same day. Schneider Electric says Canadian buyers can obtain the charger through electrical distributors and selected online retail channels, with additional in-store retail availability planned later in 2026.
SmartAmp adjusts charging to household demand
The distinguishing feature is Schneider Electric’s SmartAmp dynamic load-management system. Current transformers installed at the main or subpanel monitor household electrical load. The charger then adjusts its charging output as demand from other household equipment changes, reducing output when available capacity is constrained and increasing it again when capacity returns.
This is a managed charging approach rather than a claim that every home can accept a 48 A charger without electrical work. Its practical value is that the EV charging load can be controlled to remain within the capacity established for the installation. Schneider Electric also states that SmartAmp continues its load-management function if Wi-Fi is unavailable; connectivity is instead relevant to app-based monitoring and scheduling.
Hardwired models and published specifications
Schneider Electric Canada lists two compatible hardwired models for SmartAmp commissioning: EVRBA48ANAMJ3400 with a J3400/NACS connector and EVRBA48ANAMJ1772 with a J1772 connector. The Canadian product range lists maximum output of 11.5 kW and 48 A, a 25-foot charging cable, and a Type 4 enclosure for indoor or outdoor use.
The company lists CSA electrical certifications alongside UL and ULC-ORD-3141-related certifications for the range. Its product material also describes the load-management system as UL 3141 certified. Connector choice, vehicle compatibility, circuit design and actual charging rate remain project-specific considerations.
What changes for installers
For electricians, the product changes the scope conversation from simply adding a fixed EV load to designing and commissioning a monitored, adjustable load. Schneider Electric says the current transformers are included with compatible hardwired units, but SmartAmp must be installed and commissioned by a licensed electrician or other qualified professional.
The manufacturer identifies its eSetup app as the commissioning tool. Installers should confirm the panel location and configuration, current-transformer routing, feeder and branch-circuit details, disconnecting and overcurrent-protection requirements, and whether the selected connector variant matches the vehicle fleet expected at the residence.
Code review remains essential
Schneider Electric says its certified power-control system can simplify load calculations where the authority having jurisdiction accepts that approach. That qualification is important: acceptance of managed-load calculations, permit requirements and applicable electrical-code interpretation can differ by province, municipality and inspection authority.
Procurement teams and contractors should therefore treat SmartAmp as a possible way to avoid an upgrade after a documented site assessment—not as a substitute for one. A project with inadequate service capacity, unsuitable panel condition, limited physical routing space or local requirements that do not recognize the proposed calculation method may still require conventional electrical upgrades.
Relevance to electrical-channel buyers
For residential electrification work, an integrated load-management charger can reduce the number of separate components compared with an EVSE plus an external energy-monitoring gateway. That may simplify quoting, bill-of-materials development and installation coordination on homes with constrained capacity.
The product is especially relevant to contractors working with Schneider Electric and Square D electrical infrastructure, but the charger should be specified as a complete, AHJ-reviewed installation. The published specifications and product documentation should be checked against the exact Canadian SKU before ordering, since connector selection and project conditions determine the final equipment package.
Sources
- Schneider Electric Launches Schneider Charge, a Level 2 Residential EV Charger with Built-In Dynamic Load Management — Business Wire
- Schneider Charge AC: Level 2 home EV charger — Schneider Electric Canada
- How Do I Activate SmartAmp Load Management? — Schneider Electric Canada
- EVRBA48ANAMJ3400: Level 2 AC EV charger, Schneider Charge, hardwired, 11.5 kW/48 A, NACS, with load management — Schneider Electric Canada
- EVRBA48ANAMJ1772: Level 2 AC EV charger, Schneider Charge, hardwired, 11.5 kW/48 A, J1772, with load management — Schneider Electric Canada