4/3 Type NM-B Wire with Ground
Minimum 1 ft. to maximum 2500 ft.. Please call for longer put ups.
Applications:
Non-metallic sheathed NM-B cable is used in normally dry installations in residential wiring, as branch circuits for outlets, lighting and other residential loads. Its applications are outlined in NEC 2008 and NEC 2011 Article 334. NM-B is rated at 600 volts and although it is rated at a conductor temperature of 90°C dry , its ampacity is limited to 60°C according to the NEC 2008 and NEC 2011. It may be fished through masonry or tile walls, where not exposed or subject to excessive moisture or dampness. NM-B cables are LEAD FREE and RoHS compliant. Equivalent to Romex NM-B.
Standards:
Meets or exceeds all applicable ASTM specifications
UL 83: Thermoplastic Insulated Wires and Cables
UL 719: Non-Metallic Cables
Federal Specification A-A-59544 and requirements of the NEC.
Voltage rating - 600 volts.
Construction:
Conductors:
Stranded 8 AWG and larger annealed soft bare copper per ASTM B3 and B8.
Insulation:
Color coded polyvinyl chloride (PVC) compound with a nylon covering meeting the required thickness of Type THHN. Conductor insulation is rated 90°C.
Ground:
Soft, bare copper solid per ASTM B3 and stranded per ASTM B3 and B8
Sheath:
30 mil color coded PVC sheath rated 90C is applied over the completed assembly
4-3 NM-B Wire Specifications*:
Size: 4 AWG
Number of Conductors: 3 + 1 Ground
Ground Wire Size: 8 AWG
Nominal Cable Dimensions: .150mils
Weight per foot: 0.556 lbs
Allowable Ampacity: 70 Amps @ 30°C PER NEC
*Data provided on this page is subject to change based on different manufacturers variances.
There are no reviews for this product.