Model:
Bosch FMM-325A-D Analog Manual Station Double Action
SKU:
FMM-325A-D
Availability:
In Stock
$113.00
  0 reviews
Condition: New Brand: Bosch Item Type: Pull Station Alarm Action: Double-Action Alarm Reset: Manual Color: White on Red Mounting: Wall Environment: Outdoor (IP65+), Corrosion Resistant Home Control: Wi-Fi Input Voltage: 24 VDC

Bosch FMM-325A-D | Digital data communications and power provided over two-wire circuit | Rugged die-cast housing and corrosion resistant construction. Buy Now.

Analog Manual Station Double Action. These manual stations are used in the polling circuit of the Bosch Security Systems, Inc.'s FPA-1000 Analog Addressable Fire Panels, and the D9024, D8024, and D10024A Fire Alarm Control Panels (FACP). They communicate with the control panel (both power and data) over a two-wire polling circuit. The manual station's address on the polling circuit is set by programming an EEPROM microchip. The D5070 Analog Device Programmer is required to set the address. All commercial buildings use manual stations. These manual stations allow people evacuating a building to initiate an alarm. The FACP identifies the alarm point on the polling circuit and the alarm lever latches in the pulled position.

  • Digital data communications and power provided over two-wire circuit
  • EEPROM addressing in module unit
  • Rugged die-cast housing and corrosion resistant construction
  • Single-gang mounting
  • Latching alarm lever

Downloads

FMM-325A-D Data Sheet
(Size: 208.2 KB)
FMM-325A-D Installation Instruction
(Size: 432.5 KB)

Bosch FMM-325A-D | Digital data communications and power provided over two-wire circuit | Rugged die-cast housing and corrosion resistant construction. Buy Now.

Analog Manual Station Double Action. These manual stations are used in the polling circuit of the Bosch Security Systems, Inc.'s FPA-1000 Analog Addressable Fire Panels, and the D9024, D8024, and D10024A Fire Alarm Control Panels (FACP). They communicate with the control panel (both power and data) over a two-wire polling circuit. The manual station's address on the polling circuit is set by programming an EEPROM microchip. The D5070 Analog Device Programmer is required to set the address. All commercial buildings use manual stations. These manual stations allow people evacuating a building to initiate an alarm. The FACP identifies the alarm point on the polling circuit and the alarm lever latches in the pulled position.

  • Digital data communications and power provided over two-wire circuit
  • EEPROM addressing in module unit
  • Rugged die-cast housing and corrosion resistant construction
  • Single-gang mounting
  • Latching alarm lever

Downloads

FMM-325A-D Data Sheet
(Size: 208.2 KB)
FMM-325A-D Installation Instruction
(Size: 432.5 KB)