The Macurco Horn and Strobe series is designed for spaces where distinctive visual or audible signal is required. These devices use low current to provide a high decibel output and can be easily seen and heard from afar. The Horn and Strobe works well with Macurco products including the DVP-120, DVP-120M control panels and the Macurco 6 & 12 Series detectors. This notification device can be flush or surface mounted on a standard 4 x 4 in electrical box.
Features
- MHG 16 - 33 VDC, HORN
- 24 VDC Nominal Voltage
- 16 - 33 VDC Operating Voltage
- Operating Environment: 32 to 120 deg F, 10 to 93% RH
- Blue
- Dimensions: 5-1/2 x 4-3/4 x 2 in
- Strobe Candela: DVP-120 & DVP-120M Control Panels, 6 & 12 Series Gas Detectors
- Approvals: UL 1638A, ULC C22.2 No.205
- Strobe Candela: DVP-120 & DVP-120M Control Panels, 6 & 12 Series Gas Detectors
- Horn Patterns: Temporal 4 High, Temporal 4 Low, Continuous High, Continuous Low (Field Selectable)
- Flexible optic design to meet or exceed the light output on vertical/horizontal dispersion
- Strobe Candela: Adjustable at 15, 30, 75 or 110 cd *Based on test result with clear lens cover
- Adjustable two audible tone settings: Continuous (high/low), Temporal 4 (high/low)
- 20 ms pulse duration
- Low current draw
- High power cool white LED is used
- Strobe flash rate: 1 flash per second
- Works with Macurco DVP-120 & DVP-120M control panels
- Works with Macurco 6 & 12 Series detectors
The Macurco Horn and Strobe series is designed for spaces where distinctive visual or audible signal is required. These devices use low current to provide a high decibel output and can be easily seen and heard from afar. The Horn and Strobe works well with Macurco products including the DVP-120, DVP-120M control panels and the Macurco 6 & 12 Series detectors. This notification device can be flush or surface mounted on a standard 4 x 4 in electrical box.
Features
- MHG 16 - 33 VDC, HORN
- 24 VDC Nominal Voltage
- 16 - 33 VDC Operating Voltage
- Operating Environment: 32 to 120 deg F, 10 to 93% RH
- Blue
- Dimensions: 5-1/2 x 4-3/4 x 2 in
- Strobe Candela: DVP-120 & DVP-120M Control Panels, 6 & 12 Series Gas Detectors
- Approvals: UL 1638A, ULC C22.2 No.205
- Strobe Candela: DVP-120 & DVP-120M Control Panels, 6 & 12 Series Gas Detectors
- Horn Patterns: Temporal 4 High, Temporal 4 Low, Continuous High, Continuous Low (Field Selectable)
- Flexible optic design to meet or exceed the light output on vertical/horizontal dispersion
- Strobe Candela: Adjustable at 15, 30, 75 or 110 cd *Based on test result with clear lens cover
- Adjustable two audible tone settings: Continuous (high/low), Temporal 4 (high/low)
- 20 ms pulse duration
- Low current draw
- High power cool white LED is used
- Strobe flash rate: 1 flash per second
- Works with Macurco DVP-120 & DVP-120M control panels
- Works with Macurco 6 & 12 Series detectors
There are no reviews for this product.