Model:
500 MCM 3C Type SHD-GC Shielded Round Power Cable, 2kV
SKU:
TSHGC5003C2KV-FT
Availability:
In Stock
  0 reviews

500 MCM 3C Type SHD-GC Shielded Round Power Cable, 2kV.

Cut to length - sold by the foot. Enter the desired footage in the QTY box.
Minimum 10' to maximum 1000'. Please call for longer put ups.

Conductor:
6 AWG thru 500 kcmil coated annealed copper, bunched wires, rope-lay-stranded per ASTM B172

Insulation:
Ethylene Propylene Rubber (EPR) insulation

Insulation Shield:
A flexible coated copper/textile braid shield is applied over non-conducting overlapped tape

Ground Check Conductor:
Annealed copper, rope-lay-stranded per ASTM B172, insulated with high-strength yellow polypropylene

Grounding Conductors:
Coated copper, rope-lay-stranded per ASTM B172
Two conductors in contact with the flexible copper braid shield

Jacket:
Reinforced, two-layer, extra-heavy-duty, lead- cured Chlorinated Polyethylene (CPE)

Applications:
Designed for use as trailing cables on AC mining equipment:
- Where a ground-check conductor is required for fail-safe monitoring
- With Bretby-type cable handling devices on longwall shearers
- Where induced voltages in the grounding system will not produce a hazard
- On low- and medium-voltage AC circuits where shielding is desired or required

Features:
Flexible insulation shield provides shock hazard protection
Excellent heat, moisture, steam, oil, chemical and radiation resistance
Flexible for easy handling
Resists cutting, impact, abrasion, flame and sunlight
Excellent thermal stability and physical properties over a broad temperature range
Two-layer jacket is reinforced to provide maximum protection from mechanical damage— the cause of most portable cable failures

Compliances:
ICEA S75-381 Portable and Power Feeder Cables for use in mines and similar applications
• Meets flame test requirements and is accepted for listing by MSHA
• Approved by the Pennsylvania Department of Environmental Protection
• Meets CAN/CSA-C22 .2 No . 96 Portable Power Cables and is certified by Natural Resources Canada

Specifications*:

Size: 500 MCM
Number of Conductors: 3
Conductor Strand: 1221
Ground Conductor AWG Size: 4/0
Ground Check AWG Size: 6
Nominal Insulation Thickness: 0.095 inches / 2.4 mm
Outside Diameter: 3.19 inches / 81.0 mm
Current AMPS: 536
Net Weight: 9.820 lbs per ft

*Data provided on this page is subject to change based on different manufacturers variances.