Warning: unlink(/website/safsale.com/www/storage/cache/cache.product.unishop.autorelated.2147481646.1.1.0.1734533481): No such file or directory in /website/safsale.com/www/system/library/cache/file.php on line 17Warning: unlink(/website/safsale.com/www/storage/cache/cache.catalog.language.1734537081): No such file or directory in /website/safsale.com/www/system/library/cache/file.php on line 68
Model:
Magnasphere HSS-L2S-004 Single Alarm Contact With Tamper Circuit, Closed Loop
SKU:
HSS-L2S-004
Availability:
In Stock
$310.00
  0 reviews
Condition: New Brand: Magnasphere Type: Hardwired Scene: Outdoor, Indoor

The HSS-L2S-004 from Magnasphere is a single alarm contact with tamper circuit, closed loop. 1K Ω series, 1K Ω parallel embedded EOL resistors on closed loop alarm contact. MAGNASPHERE has created the L2 Series HSS 'High Security Sensor' – The Next Generation of sensors for high security standards for SCIFs, safes and vaults, and all other high level secure applications. The acclaimed MAGNASPHERE HSS devices are listed to UL634 Level 2 High Security Standard. In addition to their vastly increased security they offer many labor saving installation features, including embedded EOL resistors. The L2S single alarm contacts are surface mount.

One of the unique features of the HSS L2S is the ability to add embedded EOL resistors and related electronics to offer the ultimate in security. We offer a variety of embedded EOL resistor configurations and values. In addition to the surface mount models, MAGNASPHERE has expanded its L2 series HSS product line to include the revolutionary L2C series for installations where concealed sensors are desired for both security and aesthetics.

UL634 is the standard for all switches and connectors used in alarm systems. The 9th edition (2007) eliminated the previous BMS high security categories. Learn about the difference between High Security Levels 1 & 2. The ICD 705, sets the standards for SCIF intrusion detection systems for the government Intelligence Community, and requires the use of HSS Level 2 devices.

Features

  • Resistant to External and Internal magnetic defeat
  • Built-in EOL resistors available
  • Unique cross hole mounting feature eliminates need for L and Z brackets on most installations
  • Retro-fit for existing BMS devices
  • No adjustment required for installation
  • Industry’s most secure removal tamper sensor/circuit
  • Magnasphere switch technology resists permanent contact welding (lightning, power surges, stun guns)
  • Single and dual alarm contacts available
  • American made using award-winning Magnasphere switch technology
  • Compatible with control panel models that accept contact inputs
  • Competitively priced
  • Intrinsically Safe, Simple Apparatus

Downloads

  HSS-L2S-004-Specsheet

  HSS-L2S-004-Installation-Instructions

The HSS-L2S-004 from Magnasphere is a single alarm contact with tamper circuit, closed loop. 1K Ω series, 1K Ω parallel embedded EOL resistors on closed loop alarm contact. MAGNASPHERE has created the L2 Series HSS 'High Security Sensor' – The Next Generation of sensors for high security standards for SCIFs, safes and vaults, and all other high level secure applications. The acclaimed MAGNASPHERE HSS devices are listed to UL634 Level 2 High Security Standard. In addition to their vastly increased security they offer many labor saving installation features, including embedded EOL resistors. The L2S single alarm contacts are surface mount.

One of the unique features of the HSS L2S is the ability to add embedded EOL resistors and related electronics to offer the ultimate in security. We offer a variety of embedded EOL resistor configurations and values. In addition to the surface mount models, MAGNASPHERE has expanded its L2 series HSS product line to include the revolutionary L2C series for installations where concealed sensors are desired for both security and aesthetics.

UL634 is the standard for all switches and connectors used in alarm systems. The 9th edition (2007) eliminated the previous BMS high security categories. Learn about the difference between High Security Levels 1 & 2. The ICD 705, sets the standards for SCIF intrusion detection systems for the government Intelligence Community, and requires the use of HSS Level 2 devices.

Features

  • Resistant to External and Internal magnetic defeat
  • Built-in EOL resistors available
  • Unique cross hole mounting feature eliminates need for L and Z brackets on most installations
  • Retro-fit for existing BMS devices
  • No adjustment required for installation
  • Industry’s most secure removal tamper sensor/circuit
  • Magnasphere switch technology resists permanent contact welding (lightning, power surges, stun guns)
  • Single and dual alarm contacts available
  • American made using award-winning Magnasphere switch technology
  • Compatible with control panel models that accept contact inputs
  • Competitively priced
  • Intrinsically Safe, Simple Apparatus

Downloads

  HSS-L2S-004-Specsheet

  HSS-L2S-004-Installation-Instructions