The PS-EXIT Power Supply is specifically designed to protect and optimize the performance of Adams Rite 8000/3000 Series exit devices with Motorized Latch Retraction (MLR) or Electric Latch Retraction (LR) options by delivering filtered and regulated power. This power supply is designed to provide power and control for up to two MLR or LR exit devices. Each exit device is controlled by a timer that is initiated by a switch closure. The timer is user-configured and holds the exit device(s) in the unlatched position for 2 - 60 seconds. At the end of the selected time, the exit device(s) will re-latch. If the switch controlling the exit device is closed longer than the selected time, the exit device remains unlatched until the controlling switch is released.
Features
Protection & Efficiency
- Delivers regulated and filtered clean power for increased performance
- Power and control up to two MLR or LR exit devices in single or dual input operations
- Operating mode: single or double swinging doors
Strong, durable construction
- Blue, baked enamel finish with knockouts for conduit connections
- Available with integrated fire alarm connection
- Extends warranty to 5 years on 8000 Exit Devices with MLR or LR option
Flexible design
- Exclusively designed for Adams Rite 8000/3000 Exit Devices with MLR or LR option
- Designed to power applications where access control and accessibility is required and high performance is expected
- Produces fail-secure response, with free mechanical egress, for exit devices during complete power failure
Downloads
PS-EXIT-Specsheet
PS-EXIT-Installation-Instructions
The PS-EXIT Power Supply is specifically designed to protect and optimize the performance of Adams Rite 8000/3000 Series exit devices with Motorized Latch Retraction (MLR) or Electric Latch Retraction (LR) options by delivering filtered and regulated power. This power supply is designed to provide power and control for up to two MLR or LR exit devices. Each exit device is controlled by a timer that is initiated by a switch closure. The timer is user-configured and holds the exit device(s) in the unlatched position for 2 - 60 seconds. At the end of the selected time, the exit device(s) will re-latch. If the switch controlling the exit device is closed longer than the selected time, the exit device remains unlatched until the controlling switch is released.
Features
Protection & Efficiency
- Delivers regulated and filtered clean power for increased performance
- Power and control up to two MLR or LR exit devices in single or dual input operations
- Operating mode: single or double swinging doors
Strong, durable construction
- Blue, baked enamel finish with knockouts for conduit connections
- Available with integrated fire alarm connection
- Extends warranty to 5 years on 8000 Exit Devices with MLR or LR option
Flexible design
- Exclusively designed for Adams Rite 8000/3000 Exit Devices with MLR or LR option
- Designed to power applications where access control and accessibility is required and high performance is expected
- Produces fail-secure response, with free mechanical egress, for exit devices during complete power failure