The Square D regulated power supply is designed for industrial and building automation control circuits. It offers a 12V DC output with a maximum leakage current of 0.25 mA at 240 V AC and a rated power of 12 W.

Constructed with a plastic enclosure, it supports mounting on top hat type TH35-15 rail, double-profile DIN rail, or panel mounting. The device features a dielectric strength of 3000 V AC and a power factor of 0.51 at 115 V AC.

  • Input voltage: 100 to 240 V AC single phase
  • Output voltage: 12 V DC
  • Output current: 1 A
  • Enclosure material: Plastic
  • Vibration resistance: 3 mm (f= 2-9 Hz), 10 m/s² (f= 9-200 Hz)
  • Certifications: CE, cUL Listed, cUL Recognized, RCM, CB Scheme, EAC, KC, NEC class 2

Technical Specifications

Complementary Attributes - Maximum Leakage Current0.25 mA 240 V AC
Complementary Attributes - Rated Power In W12 W
Persona Type IdsEU, OM, OM8
Persona Type NamesEnd User, Original Equipment Manufacturer, OEM - Control Panelbuilder
Current Consumption
Earthing SystemTN, TT, IT
Efficiency80 % 115 V AC, 80 % 230 V AC
Electromagnetic Compatibilityimmunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2, immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2, electromagnetic field immunity test - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3, electromagnetic field immunity test - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3, electromagnetic field immunity test - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3, immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4,
Electromagnetic Emissionconducted emissions IEC 61000-6-3, radiated emissions IEC 61000-6-4
Holding Time> 10 ms 115 V AC, > 10 ms 115 V AC, > 10 ms 115 V AC, > 60 ms 230 V AC, > 60 ms 230 V AC, > 60 ms 230 V AC, > 10 ms 115 V AC, > 10 ms 115 V AC, > 10 ms 115 V AC, > 60 ms 230 V AC, > 60 ms 230 V AC
Inrush Current15 A 115 V, 30 A 230 V
Line And Load Regulation
Mounting Supporttop hat type TH35-15 rail IEC 60715, top hat type TH35-7.5 rail IEC 60715, double-profile DIN rail, panel mounting
Power Factor0.51 at 115 V AC, 0.40 at 230 V AC
SupplySELV IEC 60950-1, SELV IEC 60204-1, SELV IEC 60364-4-41
Vibration Resistance3 mm (f= 2-9 Hz) conforming to IEC 60721-3-3, 10 m/s² (f= 9-200 Hz) conforming to IEC 60721-3-3
Connections Terminalsscrew connection 0.5...1.5 mm², AWG 20...AWG 16) without wire end ferrule input/output, screw connection 0.5...1 mm², AWG 20...AWG 18) with wire end ferrule input/output
Meantime Between Failure Mtbf3000000 h at 25 °C, full load, 1000000 h at 55 °C, 80 % load
Carbon Footprint Of The Distribution Phase A40.0147087805, 0 kg CO2 eq.
Carbon Footprint Of The End Of Life Phase C1 To C40.1 kg CO2 eq., 0.0980777727
Carbon Footprint Of The Installation Phase A50.0011673327, 0 kg CO2 eq.
Carbon Footprint Of The Manufacturing Phase A1 To A32 kg CO2 eq., 1.6085908882
Carbon Footprint Of The Use Phase B2 B3 B4 B6129 kg CO2 eq., 128.76
Certificate AgencyCE, cUL Listed, cUL Recognized, RCM, CB Scheme, EAC, KC, NEC class 2
Local Data StatusPublishable
Local Publishable Date2026-01-12
Return IndicatorY
Stocking FlagN
Stock Policy2
Device TypePLC System - PLC Component
ServiceabilityNo
TraceabilityYes
Field Service DivisionIDIBS
Use Carbon Footprint128.76
Weee ScopeIn

Product Documents

Reviews: 0

There are no reviews for this product.

Questions: 0

No questions about this product.

Similar products