The Square D DOE 2016 transformer is a 3-phase, dry type unit rated at 45 kVA, suitable for low voltage electrical distribution applications. It features copper construction, a primary voltage of 480 V delta, and a secondary voltage of 208Y/120 V. The transformer has an efficiency of 98.59% at 35% load factor and a temperature rise of 220 °C with an insulation temperature of 80 °C.
מאפייני מפתח כוללים:
- Rated operational power: 45 kVA
- Peak withstand current: 3.03 kA
- Impulse withstand voltage: 10 kV
- Thermal current rating factors up to 3890 at 100%
- Four mounting options: floor, ceiling, wall
- Noise level: 1 dB NEMA ST-20, 44 dB
- Two tap-offs at 2.5% FCAN and four at 2.5% FCBN
- Core loss: 108 no load, coil loss: 1032 load loss
- חומר: נחושת
- Network frequency: 60 Hz
Designed for a lifespan of approximately 25 years, this transformer is traceable and compliant with UL 1561, CSA C22.2 No 47, and NEMA ST-20 standards. It features environmentally conscious packaging made with recycled cardboard and is free of substances of very high concern.
הוראות טכניות
| Complementary Attributes - Rated Operational Power In Va | 45 kVA |
| Complementary Attributes - Ipk Rated Peak Withstand Current | 3.03 kA |
| Complementary Attributes - Uimp Rated Impulse Withstand Voltage | 10 kV |
| Continuous Thermal Current Rating Factor | 466 16.6 %, 589 25 %, 1249 50 %, 2349 75 %, 3890 100 % |
| Electrical Connection | 2 Hole Nema Pad secondary 11.1 mm, 4 Hole Nema Pad sec - XO 11.1 mm, 4 Hole Nema Pad primary 11.1 mm |
| Mounting Support | floor, floor, with 7400FMB, ceiling, with 7400CMB18M19M20M, wall, with 7400WMB18M19M20M |
| רמת רעש | 1 dB NEMA ST-20, 44 dB |
| Number Of Tap Offs | 2 2.5 % FCAN, 4 2.5 % FCBN |
| Tap Loss | 108 no load (core loss), 1032 load loss (coil loss) |
| עליית הטמפרטורה | 80 °C, 220 °C insulated |
| Carbon Footprint Of The Distribution Phase A4 | 43.56152401106655, 44 kg CO2 eq. |
| Carbon Footprint Of The End Of Life Phase C1 To C4 | 555 kg CO2 eq., 554.7812045379648 |
| Carbon Footprint Of The Installation Phase A5 | 11.46112375329284, 11 kg CO2 eq. |
| Carbon Footprint Of The Manufacturing Phase A1 To A3 | 1 091 kg CO2 eq., 1091.0243463551083 |
| Carbon Footprint Of The Use Phase B2 B3 B4 B6 | 13 636 kg CO2 eq., 13636.11427118664 |
| Certificate Agency | UL 1561, CSA C22.2 No 47, NEMA ST-20 |
| Local Data Status | Publishable |
| Local Publishable Date | 2025-11-13 |
| Return Indicator | Y |
| Stocking Flag | Y |
| Stock Policy | 2 |
| סוג התקן | Transformer - dry |
| Serviceability | לא. |
| Traceability | כן. |
| Field Service Division | PSIBS |
| Average Life Duration | 25 year(s) |
| Weee Scope | ב |
| Weee Product Category | 5 |
| Scope Perimeter | At least in Europe |
| Eoli Availability Display | No need of specific recycling operations |
| Reach Full Compliance Status | Free of Substances of Very High Concern above the threshold |
| Reach Full Compliance Status Id | NOT_CONTAINING_SVHC |
| Reach Compliance Directive | Free of Substances of Very High Concern above the threshold |
| Rohs Eur In Scope | כן. |
| Rohs Eur Status | Compliant |
Product Documents
Before purchasing Square D DOE 2016 45kVA 3-Phase Dry Type Transformer EXN45T3HBCU, confirm the required application, mounting style, connection type, rating, and compatibility with the rest of the system.
אין ביקורות על המוצר הזה.
No questions about this product.

Spec Sheet