$1,030.03
מחיר משוער. Final price and availability are subject to confirmation. Contact our sales team for a current quote.
The Square D TeSys T motor controller LTMR27EBD is designed for equipment monitoring and control applications. It supports communication protocols such as Modbus TCP and Ethernet/IP, enabling seamless integration into industrial networks.
Key features include:
- Communication Port Protocol: Modbus TCP/EtherNet/IP
- Ui Rated Insulation Voltage: 690 V (EN/IEC 60947-1, CSA, UL)
- Rated Impulse Withstand Voltage: 6 kV
- Maximum Operating Frequency: 2 Hz
- Maximum Operating Rate: 1800 cycles per hour
- Short Circuit Withstand: 100 kA
- Rated Supply Voltage: 24 V DC
- Input Current: 7 mA
- Device Application: Equipment monitoring and control
Constructed with halogen-free plastic parts, this relay offers robust electromagnetic compatibility and is suitable for industrial and commercial environments. It features a depth of 122.5 mm, a height of 61 mm, and a width of 91 mm.
Technical Specifications
| Communications & Management Attributes - Communication Port Protocol | Modbus TCP/EtherNet/IP |
| Complementary Attributes - Ui Rated Insulation Voltage | 690 V EN/IEC 60947-1, 690 V CSA C22.2 No 14, 690 V UL 508 |
| Complementary Attributes - Uimp Rated Impulse Withstand Voltage | 6 kV current or voltage measurement circuit EN/IEC 60947-4-1, 0.8 kV communication circuit EN/IEC 60947-4-1, 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1 |
| Complementary Attributes - Maximum Operating Frequency | 2 Hz |
| Complementary Attributes - Maximum Operating Rate | 1800 cyc/h |
| Complementary Attributes - Short Circuit Withstand | 100 kA conforming to EN/IEC 60947-4-1 |
| Complementary Attributes - Us Rated Supply Voltage | 24 V DC |
| Persona Type Ids | EU, LC, OM, OM8, PB |
| Persona Type Names | End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder |
| Market Segmentation Id | COMMERCIAL, INDUSTRIAL |
| Market Segmentation | Commercial, Industrial |
| Associated Fuse Rating | 4 A gG output, 0.5 A gG control circuit |
| Contacts Type And Composition | 1 NO + 1 NC fault signal, 3 NO |
| Electromagnetic Compatibility | temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5, control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5, electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2, control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5, communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5, relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5, relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5, radiated RF fields, 3, 10 V/m, conf |
| Fire Resistance | 650 °C EN/IEC 60695-2-12, 960 °C UL 94 |
| Load Current | 5 A 250 V AC logic output, 5 A 30 V DC logic output |
| Measurement Accuracy | +/- 30 min/year internal clock, +/- 30 min/year internal clock, 5...15 % earth fault current internal measurement, 1 % voltage 100...830 V), 3 % power factor, 5 % earth fault current external measurement, +/- 30 min/year internal clock, +/- 30 min/year internal clock, 0,02 Temperature, 1 % current, 5 % active and reactive power |
| Mechanical Robustness | vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6, vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6, shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27 |
| Metering Type | phase current I1, I2, I3 RMS, average current Iavg, imbalance current, earth-fault current, temperature |
| Network And Machine Diagnosis Type | remaining operating time before overload tripping, running hours counter/operating time, waiting time after overload tripping, phase fault and earth fault trip counters, fault recording, trip context information, trip history information, motor control command recording, starting current and time, event recording |
| Permissible Power | 480 VA AC-15), Ie = 2 A, 500000 cycles output), 30 W DC-13), Ie = 1.25 A, 500000 cycles output) |
| Protection Type | earth-leakage protection, phase failure, thermal protection, overload, overload (long time), reverse polarity protection, power factor variation, phase unbalance, thermal overload protection, load fluctuation, locked rotor |
| Protective Treatment | 12 x 24 hour cycles EN/IEC 60068-2-30, 48 h EN/IEC 60070-2-11, TH EN/IEC 60068 |
| Connections Terminals | control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible without cable end, control circuit connector 2 0.2-1.5 mm² AWG 24...AWG 14)flexible without cable end, control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)solid without cable end, control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible with cable end, control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)flexible without cable end, control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)solid without cable end, control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)flexible with cable end, control circuit connector |
| Carbon Footprint Of The Distribution Phase A4 | 0.067046646048209, 0.1 kg CO2 eq. |
| Carbon Footprint Of The End Of Life Phase C1 To C4 | 0.9966739655553013, 1 kg CO2 eq. |
| Carbon Footprint Of The Installation Phase A5 | 0.2 kg CO2 eq., 0.19926968999031228 |
| Carbon Footprint Of The Manufacturing Phase A1 To A3 | 18 kg CO2 eq., 18.12143566409332 |
| Carbon Footprint Of The Use Phase B2 B3 B4 B6 | 5 kg CO2 eq., 4.971249437669018 |
| Certificate Agency | CCC, BV, KERI, C-tick, GL, ATEX, RINA, CSA, EAC, UL, NOM, DNV, LROS (Lloyds register of shipping), ABS, RMRoS |
| Local Data Status | Publishable |
| Local Publishable Date | 2026-04-10 |
| Return Indicator | Y |
| Stocking Flag | N |
| Stock Policy | 2 |
Product Documents
Reviews: 0
There are no reviews for this product.
Questions: 0
No questions about this product.
Similar products

Spec Sheet