Model:
Macurco DVP-120M Addressable Detection and Ventilation Control Panel
SKU:
DVP-120M
Availability:
In Stock
$1,289.78
  0 reviews
Condition: New Brand: Macurco

The DVP-120M exhaust fan controller provides automatic control to help maintain an acceptable environment in parking garages or other facilities. The DVP-120M system is designed to meet specifications for safety in enclosed parking garages, including the Uniform Building Code and OSHA 50ppm CO requirements. Using the Macurco MRS-485 Modbus adapter and 6-Series detectors, the DVP-120M can control up to 87 addressable gas detectors.

Product Features

  • External keypad for user selection of the transducer/alarm display and setting the configuration
  • Externally visible LCD display showing the status of each transducer and relay
  • Three RS-485 digital input channels - 29 addressable sensors per channel
  • Externally visible system, alarm and relay status indicators
  • Compatible with all Macurco 6-Series gas detectors and MRS-485 adapter
  • Twelve analog (current loop) input channels
  • Three 10A, 240 VAC SPDT fan/alarm relays
  • Drivers for external Horn and Strobe
  • Fail safe operation can be implemented
  • Lockable NEMA-1 type enclosure
  • Modular input and output connectors
  • ETL Listed to UL 508A, CAN/CSA-C22.2 No. 14-13
  • Up to three ventilation control zones can be defined
  • Each zone can be controlled based on transducer signals and/or time of day

Installation & Connection

Gas detection and exhaust fan control is provided by a Macurco DVP-120M system. System wiring includes main power connection for the DVP-120M, 4-20mA current loop, RS-485 serial interface and 24VDC power connections between the remote detectors and the DVP-120M, the fan control and alarm connections from the DVP-120M to the building ventilation and automation systems. The DVP-120M control panel has three relays which can be used for ventilation fan control or alarm signaling. The ventilation control function operates independently from the alarm function. It provides the ability to configure the DVP-120M for control of one to three zones. Each zone can respond to gas levels at one or more of the sensors, with configurable rising and falling concentrations for each gas type. Each zone can also be controlled based on the time of day.

The DVP-120M exhaust fan controller provides automatic control to help maintain an acceptable environment in parking garages or other facilities. The DVP-120M system is designed to meet specifications for safety in enclosed parking garages, including the Uniform Building Code and OSHA 50ppm CO requirements. Using the Macurco MRS-485 Modbus adapter and 6-Series detectors, the DVP-120M can control up to 87 addressable gas detectors.

Product Features

  • External keypad for user selection of the transducer/alarm display and setting the configuration
  • Externally visible LCD display showing the status of each transducer and relay
  • Three RS-485 digital input channels - 29 addressable sensors per channel
  • Externally visible system, alarm and relay status indicators
  • Compatible with all Macurco 6-Series gas detectors and MRS-485 adapter
  • Twelve analog (current loop) input channels
  • Three 10A, 240 VAC SPDT fan/alarm relays
  • Drivers for external Horn and Strobe
  • Fail safe operation can be implemented
  • Lockable NEMA-1 type enclosure
  • Modular input and output connectors
  • ETL Listed to UL 508A, CAN/CSA-C22.2 No. 14-13
  • Up to three ventilation control zones can be defined
  • Each zone can be controlled based on transducer signals and/or time of day

Installation & Connection

Gas detection and exhaust fan control is provided by a Macurco DVP-120M system. System wiring includes main power connection for the DVP-120M, 4-20mA current loop, RS-485 serial interface and 24VDC power connections between the remote detectors and the DVP-120M, the fan control and alarm connections from the DVP-120M to the building ventilation and automation systems. The DVP-120M control panel has three relays which can be used for ventilation fan control or alarm signaling. The ventilation control function operates independently from the alarm function. It provides the ability to configure the DVP-120M for control of one to three zones. Each zone can respond to gas levels at one or more of the sensors, with configurable rising and falling concentrations for each gas type. Each zone can also be controlled based on the time of day.