Macurco TX-6-AM-W Ammonia AM Fixed Gas Detector Controller & Transducer Overview
The Macurco TX-6-AM is a low voltage, dual relay Ammonia (NH3) detector, controller and transducer. The TX-6-AM has select-able 4-20 mA output, buzzer and digital display options. It is an electronic detection system used to measure the concentration of NH3, provide feedback and automatic exhaust fan control to help reduce NH3 concentrations in warehouses, industrial refrigeration or other commercial applications. The TX-6-AM is a low level meter capable of displaying from 0-100 ppm of Ammonia.
Product Features
- Fan relay actuation: select-able from 15 to 75 ppm NH3
- Output: Fan relay, Alarm relay and 4-20mA current loop
- Controls: Digital display (0-100 ppm), buzzer, fan delay, fan minimum run time
- Mounts on a standard 4" x 4" electrical box
- 5 A SPDT fan relay controls valves, louvers or exhaust fans
- 0.5 A N.O. or N.C alarm relay connects to warning devices or control panels
- 4-20mA current loop - compatible with the Macurco DVP-120 Control Panel
- Factory calibrated
- Supervised system design: detector problem will cause the fan & alarm relay to activate
- Optional calibration kit allows the TX-6-AM to be field tested and calibrated
- ETL Listed to UL 61010-1
- White housing
Downloads
Macurco TX-6-AM-W Ammonia AM Fixed Gas Detector Controller & Transducer Overview
The Macurco TX-6-AM is a low voltage, dual relay Ammonia (NH3) detector, controller and transducer. The TX-6-AM has select-able 4-20 mA output, buzzer and digital display options. It is an electronic detection system used to measure the concentration of NH3, provide feedback and automatic exhaust fan control to help reduce NH3 concentrations in warehouses, industrial refrigeration or other commercial applications. The TX-6-AM is a low level meter capable of displaying from 0-100 ppm of Ammonia.
Product Features
- Fan relay actuation: select-able from 15 to 75 ppm NH3
- Output: Fan relay, Alarm relay and 4-20mA current loop
- Controls: Digital display (0-100 ppm), buzzer, fan delay, fan minimum run time
- Mounts on a standard 4" x 4" electrical box
- 5 A SPDT fan relay controls valves, louvers or exhaust fans
- 0.5 A N.O. or N.C alarm relay connects to warning devices or control panels
- 4-20mA current loop - compatible with the Macurco DVP-120 Control Panel
- Factory calibrated
- Supervised system design: detector problem will cause the fan & alarm relay to activate
- Optional calibration kit allows the TX-6-AM to be field tested and calibrated
- ETL Listed to UL 61010-1
- White housing