Model:
LC1K09008P7
Availability:
In Stock
Documents:
Spec Sheet
$97.62
  0 reviews

The Schneider Electric TeSys K contactor provides reliable control for non-inductive load applications. It features four poles with a contact configuration of 2 normally open (NO) and 2 normally closed (NC). The device is rated for operational voltages up to 440V AC-1 and includes a 230V 50/60Hz control coil.

Constructed with a compact 45mm width, it supports DIN-rail mounting or screw fixing, making it suitable for various control panel configurations. Connection is made via screw clamp terminals, with a recommended tightening torque of 0.8-1.3 N.m. The contactor is certified under multiple standards including IEC, UL, CSA, CCC, and EAC, ensuring compliance with international safety and performance requirements.

  • Four-pole contactor with 2 NO + 2 NC contacts
  • Rated for 20A at up to 690V AC-1
  • Control circuit voltage of 230V AC 50/60Hz
  • Connection via screw clamp terminals
  • Compact design with 45mm width
  • Certified under IEC, UL, CSA, CCC, and EAC standards

Technical Specifications

Complementary Attributes - Control Circuit Voltage Limitsoperational: 0.8...1.15 Uc (at <50 °C), drop-out: >= 0.20 Uc (at <50 °C)
Complementary Attributes - Rated Breaking Capacity110 A at 220...230 V conforming to IEC 60947, 110 A at 380...400 V conforming to IEC 60947, 110 A at 415 V conforming to IEC 60947, 110 A at 440 V conforming to IEC 60947, 80 A at 500 V conforming to IEC 60947, 70 A at 660...690 V conforming to IEC 60947
Complementary Attributes - Icw Rated Short Time Withstand Current90 A 50 °C - 1 s for power circuit, 85 A 50 °C - 5 s for power circuit, 80 A 50 °C - 10 s for power circuit, 60 A 50 °C - 30 s for power circuit, 45 A 50 °C - 1 min for power circuit, 40 A 50 °C - 3 min for power circuit, 20 A 50 °C - >= 15 min for power circuit
Complementary Attributes - Uc Control Circuit Voltage230 V AC 50/60 Hz, 230 V
Complementary Attributes - Ue Rated Operational Voltagepower circuit <= 690 V AC <= 400 Hz, signalling circuit <= 690 V AC <= 400 Hz
Complementary Attributes - Ui Rated Insulation Voltagepower circuit 600 V UL 508, power circuit 690 V IEC 60947-4-1, power circuit 600 V CSA C22.2 No 14
Complementary Attributes - Control Circuit TypeAC 50/60 Hz
Complementary Attributes - Irms Rated Making Capacity110 A AC for power circuit conforming to IEC 60947
Complementary Attributes - Maximum Operating Rate3600 cyc/h
Complementary Attributes - Ie Rated Operational Current20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
Complementary Attributes - Uimp Rated Impulse Withstand Voltage8 kV
Persona Type IdsEU, LC, OM, OM8, PB, SI
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder, System Integrator
Market Segmentation IdCOMMERCIAL, INDUSTRIAL
Market SegmentationCommercial, Industrial
Associated Fuse Rating25 A gG at <= 440 V for power circuit, 25 A aM for power circuit
Flame RetardanceV1 conforming to UL 94, requirement 2 conforming to NF F 16-101, requirement 2 conforming to NF F 16-102
Mechanical Robustnessshocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27, shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27, vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6, vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
Mounting Supportrail, plate
Operating Time10...20 ms coil de-energisation and NO opening, 10...20 ms coil energisation and NO closing, 15...25 ms coil de-energisation and NC closing, 5...15 ms coil energisation and NC opening
Protective TreatmentTC IEC 60068, TC DIN 50016
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Signalling Circuit Frequency<= 400 Hz, <= 400 Hz
Tightening Torque0.8-1.3 N.m screw clamp terminals Philips No 2, 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm, 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Connections Terminalsscrew clamp terminals 2 0.75-4 mm²flexible without cable end, screw clamp terminals 2 0.34-1.5 mm²flexible with cable end, screw clamp terminals, screw clamp terminals 1 1.5-4 mm²solid, screw clamp terminals 1 0.75-4 mm²flexible without cable end, screw clamp terminals 1 0.34-2.5 mm²flexible with cable end, screw clamp terminals 2 1.5-4 mm²solid
Icw Rated Short Time Withstand Current90 A 50 °C - 1 s for power circuit, 85 A 50 °C - 5 s for power circuit, 80 A 50 °C - 10 s for power circuit, 60 A 50 °C - 30 s for power circuit, 45 A 50 °C - 1 min for power circuit, 40 A 50 °C - 3 min for power circuit, 20 A 50 °C - >= 15 min for power circuit
Ith Conventional Free Air Thermal Current20 A (at 60 °C) for power circuit, 10 A (at 50 °C) for signalling circuit
Carbon Footprint Of The Distribution Phase A40.35474462234016035, 0.4 kg CO2 eq.
Carbon Footprint Of The End Of Life Phase C1 To C40.25761189519253946, 0.3 kg CO2 eq.
Carbon Footprint Of The Installation Phase A50 kg CO2 eq., 0.02438721956318318
Carbon Footprint Of The Manufacturing Phase A1 To A30.9 kg CO2 eq., 0.9191500378989131
Carbon Footprint Of The Use Phase B2 B3 B4 B657 kg CO2 eq., 56.65241524409137
Certificate AgencyCB Scheme, CCC, UL, CSA, EAC, CE, UKCA
Local Data StatusPublishable
Local Publishable Date2025-02-26

Product Documents

Reviews: 0

There are no reviews for this product.

Questions: 0

No questions about this product.