Model:
LUCA12FU
Availability:
In Stock
Documents:
Spec Sheet
$189.18
  0 reviews

The Square D TeSys U control unit is a versatile device intended for use with power bases LUB12, LUB32, and LUB38 to create a TeSys U starter controller. It provides comprehensive motor protection features including overload, short circuit, phase loss, and insulation fault detection. The control unit is suitable for 3-phase motor applications up to 5.5kW at 400V.

  • Rated current: 3-12A (adjustable)
  • Overload tripping class: 10
  • Short circuit withstand: 13 times Irmax
  • Overcurrent protection: 14.2 times Ir
  • Control voltage: 110-240V AC/DC
  • Rated insulation voltage: 690V IEC 60947-6-2
  • Operational voltage: 690V AC
  • Impulse withstand voltage: 6 kV IEC 60947-6-2
  • Operating time: approximately 35-50 ms depending on control circuit
  • Dimensions: 66 mm height, 45 mm width, 60 mm depth

Certified for use with various standards including IEC, UL, CSA, CCC, EAC, and Marine, when used with compatible power bases.

Technical Specifications

Complementary Attributes - Control Circuit Voltage Limits55 V DC 110...220 V drop-out, 88...264 V AC 110...240 V in operation, 88...242 V DC 110...220 V in operation, 55 V AC 110...240 V drop-out
Complementary Attributes - Uc Control Circuit Voltage110...240 V AC, 110...220 V DC
Complementary Attributes - Ui Rated Insulation Voltage690 V IEC 60947-6-2, 600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1
Complementary Attributes - Ue Rated Operational Voltage690 V AC
Complementary Attributes - Uimp Rated Impulse Withstand Voltage6 kV IEC 60947-6-2
Persona Type IdsEU, LC, OM, OM8, PB
Persona Type NamesEnd User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder
Market Segmentation IdCOMMERCIAL, INDUSTRIAL
Market SegmentationCommercial, Industrial
Device Applicationmotor control, motor protection
Fire Resistance960 °C parts supporting live components IEC 60695-2-12, 650 °C IEC 60695-2-12
Function Availableprotection against overload and short-circuit, manual reset, earth fault protection, protection against phase failure and phase imbalance
Heat Dissipation2-2 W control circuit with LUB12, 3-3 W control circuit with LUB32, 3-3 W control circuit with LUB38
Motor Power Kw5.5 kW 400...440 V AC 50/60 Hz, 5.5 kW 500 V AC 50/60 Hz, 9 kW 690 V AC 50/60 Hz
Non Dissipating Shock Wave1 kV serial mode IEC 60947-6-2, 2 kV common mode IEC 60947-6-2
Operating Time50 ms closing with LUB32 control circuit, 50 ms closing with LUB38 control circuit, 35 ms opening with LUB12 control circuit, 35 ms opening with LUB32 control circuit, 35 ms opening with LUB38 control circuit, 50 ms closing with LUB12 control circuit
Resistance To Electrostatic Discharge8 kV 3 in open air IEC 61000-4-2, 8 kV 4 on contact IEC 61000-4-2
Resistance To Fast Transients2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4
Safe Separation Of Circuit400 V SELV between the control and auxiliary circuits IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Shock Resistance10 gn power poles open IEC 60068-2-27, 15 gn power poles closed IEC 60068-2-27
Thermal Overload Classclass 10 40-60 Hz -25-70 °C IEC 60947-6-2, class 10 40-60 Hz -25-70 °C UL 508
Typical Current Consumption280 mA 110...220 V DC I maximum while closing with LUB32, 280 mA 110...220 V DC I maximum while closing with LUB38, 25 mA 110...240 V AC I rms sealed with LUB38, 35 mA 110...220 V DC I rms sealed with LUB12, 25 mA 110...220 V DC I rms sealed with LUB32, 25 mA 110...220 V DC I rms sealed with LUB38, 280 mA 110...240 V AC I maximum while closing with LUB12, 280 mA 110...240 V AC I maximum while closing with LUB32, 280 mA 110...240 V AC I maximum while closing with LUB38, 280 mA 110...220 V DC I maximum while closing with LUB12, 35 mA 110...240 V AC I rms sealed with LUB12, 25 mA 110...240 V AC I
Utilisation CategoryAC-41, AC-43, AC-44
Vibration Resistance2 gn 5-300 Hz power poles open IEC 60068-2-6, 4 gn 5-300 Hz power poles closed IEC 60068-2-6
Carbon Footprint Of The Distribution Phase A40.06838356635823767, 0.1 kg CO2 eq.
Carbon Footprint Of The End Of Life Phase C1 To C40.31296898800484324, 0.3 kg CO2 eq.
Carbon Footprint Of The Installation Phase A50 kg CO2 eq., 0.009708208612935209
Carbon Footprint Of The Manufacturing Phase A1 To A31 kg CO2 eq., 1.1947135351162859
Carbon Footprint Of The Use Phase B2 B3 B4 B615 kg CO2 eq., 14.924864966718356
Certificate AgencyCE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine
Local Data StatusPublishable
Local Publishable Date2026-03-26
Return IndicatorY
Stocking FlagY
Stock Policy1