Modelo:
SEQ1U
SKU:
SEQ1U
Disponibilidad:
En stock
$1,390.40
Precio estimado. El precio final y la disponibilidad están sujetos a confirmación. Póngase en contacto con nuestro equipo de ventas para obtener un presupuesto actual.
  0 reviews

The SURGEX Programmable Sequencer Surge Eliminator SEQ1U is designed to manage electrical surges effectively.

The SURGEX Programmable Sequencer Surge Eliminator SEQ1U is designed to manage electrical surges effectively. It features a load rating of 20 A @ 120 V and meets various certifications including UL 1449 Adjunct Classification Test Results: 1,000 surges, 6,000 V, 3,000 A, B3 pulse Measured suppressed voltage: 170 V, no failures. It also complies with Federal Guidelines: Grade A, Class 1, Mode 1 (CID A-A-55818). The device includes a surge let-through voltage of 0 V for 6,000 V surge and supports multiple control inputs such as momentary switch, latching switch, contact closure, or 5 to 30 VDC.

It has a current rating of 3 mA for input control and 40 mA for contact closure maximum resistance. The output provides DC: 12 VDC, 40 mA maximum load with an auxiliary relay contact rating of 30 VDC at 1 A. The unit operates within a temperature range of 41 to 95ºF (5 to 35ºC) and humidity range of 5 to 95% R.H., non-condensing. It also includes listings for UL 1449 3rd Edition (Pending), UL 1283 5th Edition (Pending), and CSA C22.2 No.8-M1986 (R2008) (Pending).

The dimensions are 1.75 x 19.0 x 12.25" (4.40 x 48.30 x 31.00 cm).

  • Load Rating: 20 A @ 120 V
  • Certifications & Approvals: UL 1449 Adjunct Classification Test Results: 1,000 surges, 6,000 V, 3,000 A, B3 pulse Measured suppressed voltage: 170 V, no failures Federal Guidelines: Grade A, Class 1, Mode 1 (CID A-A-55818) EMI/RFI Filter, Normal Mode (50 Ω load): > 30 dB at 100 KHz to 50 MHz EMI/RFI Filter, Common Mode (50 Ω load): > 20 dB (1 to 50 MHz) Under-Voltage Auto Shutdown: Adjustable from 90 to 110 V Over-Voltage Auto Shutdown: Adjustable from 130 to 150 V
  • Safety: Surge Let-Through Voltage (6,000 V surge): 0 V Maximum Applied Surge Voltage: 6,000 V Maximum Applied Surge Current: Unlimited, due to current limiting Maximum Applied Surge Energy: Unlimited, due to current limiting Endurance (C62.41-1991 Category B3 pulses): 1 kV > 500,000, 3 kV > 10,000, 6 kV > 1,000 Maximum Load Inrush Energy: 1,400 Joules total during power-up
  • Control Input: Momentary Switch, Latching Switch, Contact Closure, or 5 to 30 VDC
  • Current: Input Control Current: 3 mA Contact Closure Maximum Resistance: 40 mA

Especificaciones

Dimensiones de la caja (LxWxH)
21.4 x 15 x 6.2"
Entrada de control
Momentary Switch, Latching Switch, Contact Closure, or 5 to 30 VDC
Corriente
Input Control Current: 3 mA Contact Closure Maximum Resistance: 40 mA
Retraso
1 to 40 seconds in 1 second increments
Dimensiones
1.75 x 19.0 x 12.25" (4.40 x 48.30 x 31.00 cm)
Gama de humedad
5 to 95% R.H., non-condensing
Listado
UL 1449 3rd Edition (Pending), UL 1283 5th Edition (Pending), CSA C22.2 No.8-M1986 (R2008) (Pending)
Calificación de la carga
20 A @ 120 V
Producto
DC: 12 VDC, 40 mA maximum load Auxiliary Relay Contact Rating: 30 VDC at 1 A
Peso del envase
16.42 lb
Resistencia
12 VDC Output Maximum Current: 100 Ω
Seguridad
Surge Let-Through Voltage (6,000 V surge): 0 V Maximum Applied Surge Voltage: 6,000 V Maximum Applied Surge Current: Unlimited, due to current limiting Maximum Applied Surge Energy: Unlimited, due to current limiting Endurance (C62.41-1991 Category B3 pulses): 1 kV > 500,000, 3 kV > 10,000, 6 kV > 1,000 Maximum Load Inrush Energy: 1,400 Joules total during power-up
Rango de temperatura
41 to 95ºF (5 to 35ºC)
Peso
13.0 libras (5.9 kg)
Certificaciones y aprobaciones
UL 1449 Adjunct Classification Test Results: 1,000 surges, 6,000 V, 3,000 A, B3 pulse Measured suppressed voltage: 170 V, no failures Federal Guidelines: Grade A, Class 1, Mode 1 (CID A-A-55818) EMI/RFI Filter, Normal Mode (50 Ω load): > 30 dB at 100 KHz to 50 MHz EMI/RFI Filter, Common Mode (50 Ω load): > 20 dB (1 to 50 MHz) Under-Voltage Auto Shutdown: Adjustable from 90 to 110 V Over-Voltage Auto Shutdown: Adjustable from 130 to 150 V