Product Overview

1.15 MVA Hermetically Sealed Substation Transformer - 4160V Delta Primary, 2300V Delta/Wye Secondary - ONAN, Grey is a product intended for professional commercial and industrial applications.

Key Specifications

  • Transformer Features: The industrial transformer features a primary voltage of three-phase 4160V Delta and a secondary voltage of three-phase 2300V Delta/Wye. This system carries the following ratings: 1.15 MVA (1150 KVA). The unit has a primary radial feed and live front primary connections. We also offer systems with loop feed and dead front primary connections. This transformer features a 5-position tap changer with two +2.5% taps above and two -2.5% taps below to allow small changes in voltage.
  • Temperature Rise: This unit features a 45°C ambient temperature rating and a 65°C temperature rise for reduced heat waste, increased reliability, and longer life. At 65°C temperature rise, the transformer offers 1.15 MVA (1150 KVA). The transformer meets standard efficiency requirements. The combination of low temperature rise and high efficiency makes this unit suitable for use in electrical rooms, air conditioned spaces in buildings, underground vaults and similar locations, in addition to outdoor areas.
  • Insulation Fluid: The MT-PSTH-R7-3P-DNF-1.15MVA-D.YRR-HNS-LNS-A6-BM-CZ-1ZZ-M1 features mineral oil (ONAN).
  • Gauges: The following gauges are included with the system: oil level indicator, oil thermometer, and pressure/vacuum gauge. Standard oil level indicator, oil thermometer, and pressure/vacuum gauges are analog, manual reading types. These gauges do not have alarm contacts.
  • Fault Pressure Devices: There are no fault pressure devices on the unit. Fault pressure devices are used to detect high rates of pressure rise within the tank.
  • Rapid Rise Relay: There are no rapid rise relays on the unit. This safety component is designed for protection when a rapid increase in tank pressure occurs. The relay is suitable for detecting sudden pressure fluctuations above predetermined safe limits.
  • Surge arresters: This system doesn't come with surge arresters on the primary or secondary sides. Designed for over-voltage and transient voltage protection, the components prevent damage caused by lightning, internal switching or voltage surges. We can offer models without high elbow surge arresters that have mounting provisions for customer-provided surge arresters.
  • Load Breaker Switch: The transformer is not equipped with a load breaker switch.
  • Valves: The MT-PSTH-R7-3P-DNF-1.15MVA-D.YRR-HNS-LNS-A6-BM-CZ-1ZZ-M1 is equipped with an oil drain valve, an oil sampling valve, and a pressure relief valve.
  • Protection Fuses: This transformer does not have bayonet protection fuses on the primary side. For units without protection fuses, upstream protection is provided. We recommend provisions for protection fuses when possible, as blown fuses may require more frequent oil changes.

This item is grouped with Medium Voltage Pad Mount Transformers.

Before ordering: Verify ratings, dimensions, compatibility, and installation requirements before ordering.

Specifications

Applications
General purposes, industrial sites, electrical rooms, underground vaults, manufacturing facilities, steel plants, offshore, commercial, military, processing plants, electric power distribution, utilities, and more.
Benefits
The MT-PSTH-R7-3P-DNF-1.15MVA-D.YRR-HNS-LNS-A6-BM-CZ-1ZZ-M1 transformer offers many benefits to consumers. This transformer provides owners with significant energy savings, as well as offering environmental benefits. Higher efficiency not only extends the life of the transformer, but also turns into cost savings for owners in the form of lower energy bills and decreased cost of ownership.
Fault Pressure Devices
There are no fault pressure devices on the unit. Fault pressure devices are used to detect high rates of pressure rise within the tank.
Gauges
The following gauges are included with the system: oil level indicator, oil thermometer, and pressure/vacuum gauge. Standard oil level indicator, oil thermometer, and pressure/vacuum gauges are analog, manual reading types. These gauges do not have alarm contacts.
Insulation Fluid
The MT-PSTH-R7-3P-DNF-1.15MVA-D.YRR-HNS-LNS-A6-BM-CZ-1ZZ-M1 features mineral oil (ONAN).
Load Breaker Switch
The transformer is not equipped with a load breaker switch.
Mount
This hermetically sealed transformer
Protection Fuses
This transformer does not have bayonet protection fuses on the primary side. For units without protection fuses, upstream protection is provided. We recommend provisions for protection fuses when possible, as blown fuses may require more frequent oil changes.
Rapid Rise Relay
There are no rapid rise relays on the unit. This safety component is designed for protection when a rapid increase in tank pressure occurs. The relay is suitable for detecting sudden pressure fluctuations above predetermined safe limits.
Surge arresters
This system doesn't come with surge arresters on the primary or secondary sides. Designed for over-voltage and transient voltage protection, the components prevent damage caused by lightning, internal switching or voltage surges. We can offer models without high elbow surge arresters that have mounting provisions for customer-provided surge arresters.
Temperature Rise
This unit features a 45°C ambient temperature rating and a 65°C temperature rise for reduced heat waste, increased reliability, and longer life. At 65°C temperature rise, the transformer offers 1.15 MVA (1150 KVA). The transformer meets standard efficiency requirements. The combination of low temperature rise and high efficiency makes this unit suitable for use in electrical rooms, air conditioned spaces in buildings, underground vaults and similar locations, in addition to outdoor areas.
Terminal Connections
The primary and secondary terminal connections are located on the side of the transformer. We can configure the location to be top located or top located for both the high voltage and low voltage sides.
Transformer Features
The industrial transformer features a primary voltage of three-phase 4160V Delta and a secondary voltage of three-phase 2300V Delta/Wye. This system carries the following ratings: 1.15 MVA (1150 KVA). The unit has a primary radial feed and live front primary connections. We also offer systems with loop feed and dead front primary connections. This transformer features a 5-position tap changer with two +2.5% taps above and two -2.5% taps below to allow small changes in voltage.
Valves
The MT-PSTH-R7-3P-DNF-1.15MVA-D.YRR-HNS-LNS-A6-BM-CZ-1ZZ-M1 is equipped with an oil drain valve, an oil sampling valve, and a pressure relief valve.