Model:
MPD-CS-SF6-3P-245KV-1600A-SBM-HM-N3R.C
SKU:
MPD-CS-SF6-3P-245KV-1600A-SBM-HM-N3R.C
Availability:
In Stock
Documents:
Spec Sheet
$161,338.46
Estimated price. Final price and availability are subject to confirmation. Contact our sales team for a current quote.
  0 reviews

Product Overview

245 kV SF6 Circuit Switcher, 1600 Amp, 3-Pole, Structure Base Mount, Horizontal Mount, NEMA 3R (Controls) is a product intended for professional commercial and industrial applications.

Key Specifications

  • Unit Type: SF6 Circuit Switcher, No Integrated Disconnect Switch
  • Phase: Three Phase
  • Nominal Voltage: 245kV
  • Rated Maximum Voltage: 245kV
  • Rated Lightning Impulse Withstand Voltage (BIL): 1050 kV
  • Rated Voltage Range Factor: 1.0
  • Rated Primary-Bus Fault Breaking Current: 20kA
  • Rated Short-Circuit Making Current: Per manufacturer design for 20kA class
  • Rated Short-Time Withstand Current Duration: 3 sec
  • Rated Interrupting Time: 3.0 Cycles

This item is grouped with 400A-600A Non-Fused Disconnect Switches - Wall Mount Disconnects.

Before ordering: Verify ratings, dimensions, compatibility, and installation requirements before ordering.

Specifications

AC Heater, Receptacle Voltage
2
Altitude
3,300 ft Above Sea Level
Approximate Weight
8,750 lbs (estimated)
Construction
Phase poles securely affixed to a base of frame
Cont. Current Rating
1600A
Control Cabinet Finish
ANSI 49 Grey
Control Cabinet Rating
NEMA 3R
Control Voltage
90-140V DC
Fault Closing, Duty-Cycle, Two-Time
30,000
Frequency
60Hz
HV Terminal Type
NEMA 4-Hole Pads
Ice/Snow Load
20 psf
Maximum Closing Time
5 sec
Min. Creepage
Per ANSI/IEEE standard for applicable voltage class
Min. Operating SF6 Pressure (@ 20°C)
Per manufacturer standard
Mounting
Structure Base Mount, Horizontal Mount
Nominal Voltage
245kV
Number of Close Coils
(1)
Number of Trip Coils
(2)
Operating Mechanism Supply Voltage
120 Volts AC / 125 Volts DC
Operating Range of Trip Coils
87.5 to 144 Volts DC
Operating Temperature Range
-30°C to 40°C
Operation
Motor-Operated with Manual Backup
Operation Mechanism
Motor Drive Mechanism
Overall Dimensions
310 in W x 60 in D x 195 in H (estimated)
Rated Interrupting Time
3.0 Cycles
Rated Lightning Impulse Withstand Voltage (BIL)
1050 kV
Rated Maximum Voltage
245kV
Rated Operating Sequence
C-O
Rated Primary-Bus Fault Breaking Current
20kA
Rated Short-Circuit Making Current
Per manufacturer design for 20kA class
Rated Short-Time Withstand Current Duration
3 sec
Rated Voltage Range Factor
1.0
Seismic Zone
Low, IEEE 693
SF6 Fill Pressure (@ 20°C)
Per manufacturer standard
SF6 Weight
TBD
Shipping Dimensions
TBD
Unit Type
SF6 Circuit Switcher, No Integrated Disconnect Switch
Wind Speed Rating
100 mph

Technical

Phase
Three Phase
Reviews: 0

There are no reviews for this product.

Questions: 0

No questions about this product.

Spec Sheet 494.02 KB