Model:
VFD-3P-380V-500HP-546A-DCM-N4
SKU:
VFD-3P-380V-500HP-546A-DCM-N4
Availability:
In Stock
Documents:
Spec Sheet
$94,012.22
Estimated price. Final price and availability are subject to confirmation. Contact our sales team for a current quote.
  0 reviews

Product Overview

500 HP Variable Frequency Device - 380V AC 3PH Input 480V AC 3PH Output - 546 Amps - 360kW - NEMA 4 Enclosure is a product intended for professional commercial and industrial applications.

Key Specifications

  • Unit Type: 3 Phase Delta, 3 Wire Variable Frequency Device
  • Dimensions: 30.39"-W x 17.4"-D x 44.9"-H
  • Weight: 536 lbs
  • Input Voltage: 380V AC 3PH/480V AC 3PH
  • Output Voltage: 480V AC 3PH
  • Output Current: 546 Amps
  • Operating Frequency: 50/60 Hz (0.01 to 120 Hz)
  • Kilowatts: 360 kW
  • HP: 500
  • Cooling Method: Forced air cooling

This item is grouped with 440V 460V 480V Variable Frequency Drives (VFDs).

Before ordering: Verify ratings, dimensions, compatibility, and installation requirements before ordering.

Specifications

(Isolated)
Analog: 0~12V, -12V~ +12V, 4~20mA or 0~20mA, Pulse, Ext-PID, Digital: Keypad
Altitude
Below 3300ft (1000m), Derate 1% (drive current) for every 300ft above 3300 ft
Ambient Humidity
< 90 % RH Max. (Non-Condensing)
Ambient Temperature
-10°C
Control Method
V/F, Sensorless Vector, Slip Compensation, Easy Start Selectable
Cooling method
Forced air cooling
Dimensions
30.39"-W x 17.4"-D x 44.9"-H
Display
Keypad, Operation
Fault Output
Relay Output contacts (Isolated).
Fault Reset
Trip status is reset when a fault indication is active.
Frequency Accuracy
Digital: 0.01 % of Max. Output Frequency, Analog: 0.1 % of Max. Output Frequency
Ground Wire Size
4/0
HP
500
Inverter Alarms
Stall Prevention, Overload Alarm, Over Heat, Thermal Sensor Fault
Inverter Disable
Interrupts the output of the drive
Inverter Trips
Over Voltage, Low Voltage, Over Current, Ground Fault, Inverter Overheat,
Jog
Jog operation
Kilowatts
360 kW
Meter/Indicator
Output Voltage: (2) 0~10VDC Outputs (Non-Isolated): Choose from: Output
Multi-Step
Max 18 Speeds can be set including Jog, Dwell via (4) Multi-Function Terminals
Operating Frequency
50/60 Hz (0.01 to 120 Hz)
Operating Status
Relay Output contacts (Isolated). (4) Form A (Ax-Cx) - AC 250V, 1A.
Operation Functions
DC Braking, Frequency Limit, Frequency Jump, 2nd Function, Slip
Operation Method
Keypad / Terminal / Communication Operation
Output Current
546 Amps
Output Voltage
480V AC 3PH
Overload Capacity
110% per 1 min VT standard duty, 120% per 1 min CT standard duty, 150% per
Pattern
0.1~ 6,000 sec.
Pollution Degree
2, No Corrosive Gas, Combustible Gas, Oil Mist, or Dust
Power Loss
Below 8.3 msec: Continuous operation
Start Signal
Forward, Reverse
Storage Temperature
-20
Unit Type
3 Phase Delta, 3 Wire Variable Frequency Device
V/F Ratio
Linear, Squared Pattern, User V/F
Vibration
Below 5.9m/sec2
Voltage Boost
Manual Voltage Boost (0 ~ 15 % programmable), Auto Boost
Weight
536 lbs

Technical

Input Voltage
380V AC 3PH/480V AC 3PH
Resolution
Digital Reference: 0.01 Hz (Below 100 Hz), 0.1 Hz (Over 100 Hz), Analog Reference: 0.01 Hz / 60 Hz
Short Circuit Rating
100KA, Symmetrical