Model:
MT-PSTC-R7-3P-DMV-500KVA-YK-HNS-LNS-A5-AFM-CZ-Z-M1SKU:
MT-PSTC-R7-3P-DMV-500KVA-YK-HNS-LNS-A5-AFM-CZ-Z-M1Availability:
In StockDocuments:
Spec Sheet
$63,730.00
Estimated price. Final price and availability are subject to confirmation. Contact our sales team for a current quote.
Product Overview
500 KVA Conservator Substation Transformer - 11000V Delta Primary, 400Y/231V Wye-N Secondary, ONAN, Grey is a product intended for professional commercial and industrial applications.
Key Specifications
- Transformer Features: The industrial transformer features a primary voltage of three-phase 11000V Delta and a secondary voltage of three-phase 400Y/231 Wye-N. This system is rated for 500 KVA and is approved for step up or step down operations. We offer systems with loop or radial feed, as well as dead front or live front primary connections. This transformer features a 5-position off load tap changer with two, +/- 2.5% taps above and two, +/- 2.5% taps below to allow small changes for voltage. There are no rapid rise relays or protection fuses present on the system.
- Temperature Rise: his unit features a
- Insulation Fluid: The MT-PSTC-R7-3P-DMV-500KVA-YK-HNS-LNS-A5-AFM-CZ-Z-M1 features mineral oil fluid (ONAN). We offer transformers with biodegradable or FR-3 fluids, if needed.
- Biodegradable Fluid: Biodegradable cooling fluid (vegetable oil) has a higher heat capacity compared to mineral oil, making the liquid safer to use and more reliable during operations. Vegetable oil has a higher flash point and fire point than mineral oil, hydrocarbon oil, silicone oil and synthetic ester. This cooling fluid is also non-toxic and can tolerate higher breakdown voltages than mineral oil. When operating at high temperatures, biodegradable cooling liquid sustains up to 120% loan conditions, which helps preserve the transformer's lifespan and performance.
- Gauges: The following gauges are included with the system: liquid level, temperature and pressure/vacuum gauges. Standard liquid level, temperature and pressure/vacuum gauges are analog, manual reading types.
- Fault Pressure Devices: There are no fault pressure devices on the unit. Fault pressure devices are used to detect high rates of pressure rise within the tank.
- Rapid Rise Relay: There are no rapid rise relays on the unit. This safety component is designed for protection when a rapid increase in tank pressure occurs. The relay is suitable for detecting sudden pressure fluctuations above predetermined safe limits.
- Surge arresters: This system does not come with surge arresters on the primary side.
- Load Breaker Switch: The transformer is not equipped with a load break switch.
- Valves: The MT-PSTC-R7-3P-DMV-500KVA-YK-HNS-LNS-A5-AFM-CZ-Z-M1 is equipped with a pressure relief valve, fill valve and drain valve with sampler port.
This item is grouped with Medium Voltage Pad Mount Transformers.
Before ordering: Verify ratings, dimensions, compatibility, and installation requirements before ordering.
Specifications
Applications
General purposes, industrial sites, electrical rooms, underground vaults, manufacturing facilities, steel plants, offshore, commercial, military, processing plants, electric power distribution, utilities and more.
Benefits
The MT-PSTC-R7-3P-DMV-500KVA-YK-HNS-LNS-A5-AFM-CZ-Z-M1 transformer offers many benefits to consumers. This transformer provides owners with significant energy savings, as well as offering environmental benefits. Higher efficiency not only extends the life of the transformer, but also turns into cost savings for owners in the form of lower energy bills and decreased cost of ownership.
Biodegradable Fluid
Biodegradable cooling fluid (vegetable oil) has a higher heat capacity compared to mineral oil, making the liquid safer to use and more reliable during operations. Vegetable oil has a higher flash point and fire point than mineral oil, hydrocarbon oil, silicone oil and synthetic ester. This cooling fluid is also non-toxic and can tolerate higher breakdown voltages than mineral oil. When operating at high temperatures, biodegradable cooling liquid sustains up to 120% loan conditions, which helps preserve the transformer's lifespan and performance.
Fault Pressure Devices
There are no fault pressure devices on the unit. Fault pressure devices are used to detect high rates of pressure rise within the tank.
Gauges
The following gauges are included with the system: liquid level, temperature and pressure/vacuum gauges. Standard liquid level, temperature and pressure/vacuum gauges are analog, manual reading types.
Insulation Fluid
The MT-PSTC-R7-3P-DMV-500KVA-YK-HNS-LNS-A5-AFM-CZ-Z-M1 features mineral oil fluid (ONAN). We offer transformers with biodegradable or FR-3 fluids, if needed.
Load Breaker Switch
The transformer is not equipped with a load break switch.
Mount
This conservator substation should be installed on supporting structures, such as the roof of the transformer main tank.
Protection Fuses
This transformer does not have bayonet protection fuses on the primary side. For units without protection fuses, up stream protection is provided. We recommend provisions for protection fuses when possible, as blown fuses may require more frequent oil changes.
Rapid Rise Relay
There are no rapid rise relays on the unit. This safety component is designed for protection when a rapid increase in tank pressure occurs. The relay is suitable for detecting sudden pressure fluctuations above predetermined safe limits.
Surge arresters
This system does not come with surge arresters on the primary side.
Temperature Rise
his unit features a
Transformer Features
The industrial transformer features a primary voltage of three-phase 11000V Delta and a secondary voltage of three-phase 400Y/231 Wye-N. This system is rated for 500 KVA and is approved for step up or step down operations. We offer systems with loop or radial feed, as well as dead front or live front primary connections. This transformer features a 5-position off load tap changer with two, +/- 2.5% taps above and two, +/- 2.5% taps below to allow small changes for voltage. There are no rapid rise relays or protection fuses present on the system.
Valves
The MT-PSTC-R7-3P-DMV-500KVA-YK-HNS-LNS-A5-AFM-CZ-Z-M1 is equipped with a pressure relief valve, fill valve and drain valve with sampler port.
Reviews: 0
There are no reviews for this product.
Questions: 0
No questions about this product.