Compressor
Threshold: -20 to +20 dBu Ratio: 1.2:1 to infinite Attack: 0.2 to 50 ms Release 5 to 1000 ms/dB Detector: Peak/Average Attenuation Bus: 2 available Metering: In, Out, Attenuation, Graphical
Controls
Autoleveler Controls Target Level: -40 to +20 dBu Action: Gentle, Normal, Aggressive, User-Defined Maximum Gain: 0 to +22 dB Metering: Input, Gain, Attenuation Ratio: 1.2:1 to 10:1 Threshold Below Target: -30 to 0 dB Gain Increase/Decrease Rate: 5 to 1000 ms/dB Hold Time: 0 to 6 sec
Cooling
Continuously variable temperature controlled axial fans
Crossover
2 Way, 3 Way, 4 Way Crossover & High Pass / Low Pass Filters Bessel & Butterworth Filters: 12 / 18 / 24 / 48 dB/octave Linkwitz-Riley Filter: 12 / 24 / 48 dB / octave Frequency: Off, 20 Hz to 20 kHz
Current Draw
For 120 VAC Sleep Mode: 0.1 A Standby Mode: 0.7 A Idle (No Signal): 1.3 A For 240 VAC Sleep Mode: 0.05 A Standby Mode: 0.35 A Idle (No Signal): 0.65 A
Delay
At 48 kHz Sampling Rate (Input Time, Distance & Temperature): Speaker Delay: 0 to 21 ms Delay: 0 to 682 ms At 96 kHz Sampling Rate (Input Time, Distance & Temperature): Speaker Delay: 0 to 10.6 ms Delay: 0 to 341 ms
dissipation
Thermal Dissipation: Sleep Mode: <3.4 BTU/hr Standby Mode: 136 BTU/hr Idle (No signal): 238 BTU/hr Typical (1/8 Max Power @ 2 Ohms): 595 BTU/hr
Distortion
SMPTE (Typical): <0.5% THD-N (Typical): <0.5% (8 Ohms, 10 dB below rated power, 20 Hz to 20 kHz)
Gain
Gain (with / without VCA): -50 to 12 dB, off, polarity invert Digital VCA Groups: 4 available Remote RD8C Gain: Enable per channel, 0 dB to -∞ WR-5 (neWR-5) Remote Gain: 0 to -50 dB, mute
Level Control
Remote DC Level Control: Euroblock 3.5mm - GND, CV, V+ per input
Limiter
Brick Wall Limiter Threshold: -20 to 20 dBu Ratio: Infinite Attack: 0.2 to 50 ms/dB Release: 5 to 1000 ms/dB
Maximum Input Level
+21 dBu
Maximum Output Level
+21 dBu (Aux output)
Maximum Output Power
Per Channel, Low-Z Output, All Channels Driven: 2/4/8 Ohms: 400 W
Operating Range
70 to 135 VAC @ 60 Hz 140 to 270 VAC @ 50 Hz
Power Draw
Sleep Mode: <1 W Standby Mode: 40 W Idle (No Signal): 70 W
Protection Circuits
Inrush current limitation, temperature monitoring, output over-power protection, and mains fuses
Attenuation
Per Channel: Front panel, software, offset link group, and remote Fully off = Mute
Audio Metering
Range: -60 to 20 dBu Increments: 1 dB Peak Hold Indicator
AUX Outputs
Balanced Euroblock 3.5 mm
Balanced Input
Euroblock 3.5 mm, 1/4" TRS and XLR combo jack
Channel Separation
-75 dB (dB from full output, 1 kHz)
Damping Factor
>250 (8 Ohms load <1 kHz)
Data
Data Connection: Euroblock 3.5 mm - GND, 18 V, in, out
Ducking
High/Low Priority, Trigger, Filibuster, Ducked Program Trigger Threshold: -80 to +20 dBu Ducking Release: 5 to 1000 ms/dB Ducking Depth: 0 to -30 dB, -∞ Enable ducking at matrix mixer Metering input
EQ Type
For FIR Filter Output only, 48 kHz only, 2-384 taps File Type: .csv, .fir For 31-Band Filter Type: Constant Q or proportional Bandwidth: 0.499 octave to 0.25 octave For Parametric 2,4,6, or 10 Band Frequency: 20 to 20 kHz Level: -30 to 15 dB Q Value: 0.016 to 3.995 octave For Hi / Low Shelf 6 / 12 dB/octave Frequency: 20 Hz to 20 kHz Level: -15 to 15 dB For All Pass Frequency: 20 Hz to 20 kHz For Variable Q HP / LP Frequency: 20 Hz to 20 kHz Q Value: 3.047 to 0.267 For Notch / Bandpass Frequency
Filter
Input High Pass Filter: 80 Hz 2nd order
Input Source
Protea DSP Options: Analog, auto (net, AES3, analog)
Low Impedance
Bridge Mode (All Channels Driven): 4/8 Ohms: 800 W 70 V, 100 V Output (All Channels Driven): 70/100 V (Per Channel): 400 W
Mixer
Matrix Mixer: Gain (0.5 dB Increments): Off, -50 to 12 dB Mute: Per channel Auto-Mixer Enabled: Per channel Global Auto-mixer Response: 0.01 to 2 sec Enable Ducking at Mixer Ducking LED: Per channel if enabled Metering: Level, auto-mixer level
Signal Generator
Pink Noise, White Noise, Sine Wave Signal Level: Off, -50 to 20 dBu Sine Wave Frequency: 20 Hz to 12 kHz
Speaker Output
Neutrik speakON
Voltage Gain
Selectable at 26, 32, or 38 dB, or 1.4 V
Ambient Noise Compensation
Output only Max Gain: -20 to +20 dB Min/Base Gain: -40 to +20 dB Gain Change Rate: 0.2 to 20 s/dB Link Group: 16 available ANC Input Channel: 1 to 2 or 1 to 4 Noise Threshold -40 to +20 dBu Program/Ambient Gain Ratio; 0.3:1 to 3:1 Metering: Input level, Attenuation, Average noise
Audio Control Module
Dante network audio interface (pre-installed)
Feedback
48 kHz Sampling Rate 12 x filters In/Out per filter Lock (per filter) and global lock Filter Modes: Float, restricted, manual Filter Type: Notch, parametric Filter Frequency Range: 20 Hz to 20 kHz Notch Filter: -∞ Parametric Filter: 15 to -30 dB Filter Bandwidth 0.016 to 3.995 Octave Detector Sensitivity: 5 levels Float Time 5 minutes to 24 hours
Front Panel LED Indicators
White LED: Power Switch: On, off, flashing (standby mode) Red LED: Protect: On (fault condition or shut down), Off Clip / Mute (Per Channel): Clip @ 1 dB below full output / mute Blue LED: Sleep Mode: On (when the amplifier is asleep from audio inactivity) Yellow LED: Disable: On (when the power switch & front panel attenuators are disabled) Temperature (Per Channel): On dim at 90% maximum operating temperature, full bright + protect at 100% Green LED: Com: On, for Ethernet data or device ID Sig
Gate
Threshold: -80 to +20 dBu Range: Off, 100 to 0 dB Attack: 0.2 to 50 ms/dB Release: 5 to 1000 ms/dB Metering: Key signal, gate LED, graphical Advanced Gate Controls Key engage enable Key Frequency: 20 Hz to 20 kHz Key Bandwidth: 0.016 to 3.995 octave
Maximum Current Draw
All Channels Driven, Typical Input (1/8 Max Power @ 2 Ohms): 5.0 A for 120 VAC 2.5 A for 240 VAC
Network Controllers
Compatible with standard 100 MB Ethernet
Nominal
Automatic Sensing SMPS: 120 VAC @ 60 Hz 240 VAC @ 50 Hz
Preset
Euroblock 3.5 mm, close contact to GND for preset 1-4 recall
Signal to Noise
>105 dB (20 Hz to 20 kHz, un-weighted)
Standby Mode
Euroblock 3.5 mm, close contact to GND for standby mode