Model:
ISC-BDL2-WP6G
SKU:
SAFSALE-1316859
Availability:
In Stock
$51.98
Estimated price. Final price and availability are subject to confirmation. Contact our sales team for a current quote.
  0 reviews

The Bosch ISC-BDL2-WP6G Blue Line Gen2 Pet-Friendly TriTech Motion Detector features built-in PIR and microwave detection sensors with a 94° field of view, providing accurate motion detection within a 20 x 20' area. It includes pet immunity functionality to distinguish between human and pet movement, negating signals from one or two pets up to 100 lb each. First Step Processing technology reduces false alarms by analyzing motion patterns. The detector automatically adjusts sensitivity based on signal characteristics and weather conditions for reliable performance. Installation is simplified with a self-locking enclosure and built-in bubble level.

  • Current: Alarm/Standby: 10 mA at 12 VDC
  • Operating Voltage: 9-15 VDC
  • Environment: EN50130-5 Class II
  • Relative Humidity: 0 to 95%, non-condensing 0 to 85%, non-condensing (for UL-listed installation)
  • Operating Temperature: -20 to 130°F (-30 to 55°C) 32 to 120°F (0 to 49°C) (for UL-listed installation)

Specifications

Box Dimensions (LxWxH)
4.5 x 2.6 x 1.95"
Coverage
20 x 20' (6 x 6 m)
Current
Alarm/Standby: 10 mA at 12 VDC
Mounting Height
Recommended: 7.5 to 9' (2.2 to 2.8 m)
Operating Voltage
9-15 VDC
Package Weight
0.245 lb
Relative Humidity
0 to 95%, non-condensing 0 to 85%, non-condensing (for UL-listed installation)
Certifications & Approvals
USA: UL 639, FCC Europe: EN50131-2-4 Grade 2, EN50130-5 Class II, EN60529, EN50102 (IP30, IK04), 2002/95/EC, CE EN50131 Norway: FG Belgium: INCERTd France: AFNOR Sweden: INTYG Netherlands: NCP Bulgaria: GD FSPP GODKJENNELSESBEVIS Canada: CAN/ULC S306-03, IC Brazil: ANATEL China: CCC GB10408.1, GB10408.9
Relay Output
Solid state, supervised, Form A normally-closed (NC) contacts rated for ≤100 mA, 25 VDC, 2.5 W, <20 Ohms closed
Selectivity
Pet-friendly (on, off) for up to two pets up to 100 lb (45 kg)
Tamper Output
Normally-closed (NC) contacts (with cover on) rated for ≤100 mA, 25 VDC, 2.5 W Connect tamper circuit to 24-hour protection circuit

Technical

Dimensions
4.2 x 2.4 x 1.7" (10.5 x 6.1 x 4.4 cm)
Environment
EN50130-5 Class II
Frequency
10.525 GHz No alarm or setup on critical frequencies in the range from 150 kHz to 2 GHz at field strengths less than 30 V/m
Material
High-impact ABS plastic
Operating Temperature
-20 to 130°F (-30 to 55°C) 32 to 120°F (0 to 49°C) (for UL-listed installation)