$311.74
Estimated price. Final price and availability are subject to confirmation. Contact our sales team for a current quote.
The Fluke 115 digital multimeter provides a versatile solution for electrical and electronic testing in field service environments. It offers True RMS voltage and current measurements, resistance, continuity, frequency, and capacitance testing, all in a compact, ergonomic design.
Key features include:
- Ideal for quick verifications and field service tasks
- Large white LED backlight for working in poorly lit areas
- Measures AC and DC voltage to 600V
- Measures AC and DC current to 10A (20A overload for 30 seconds)
- Min/Max/Average recording to track signal fluctuations
- Includes a holster with probe holders for easy storage
- Fits into optional ToolPak™ magnetic hanger for hands-free operation
- CAT III 600V safety rated
It features a simple, one-handed operation with a backlit display for easy reading. The multimeter is equipped with a 9V battery, a 4 mm silicone test lead set, and a user manual.
Technical Specifications
| DC millivolts Range/resolution | 600.0 mV / 0.1 mV |
| DC millivolts Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 |
| DC volts Range/resolution | 6.000 V / 0.001 V60.00 V / 0.01 V600.0 V / 0.1 V |
| DC volts Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 |
| AC millivolts1True RMS Range/resolution | 600.0 mV / 0.1 mV |
| AC millivolts1True RMS Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz) |
| AC volts1True RMS Range/resolution | 6.000 V / 0.001 V60.00 V / 0.01 V600.0 V / 0.1 V |
| AC volts1True RMS Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz) |
| Continuity Range/resolution | 600 Ω / 1 Ω |
| Continuity Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of500 μs or longer. |
| Ohms Range/resolution | 600.0 Ω / 0.1 Ω6.000 kΩ / 0.001 kΩ60.00 kΩ / 0.01 kΩ600.0 kΩ / 0.1 kΩ6.000 MΩ / 0.001 MΩ || 40.00 MΩ / 0.01 MΩ |
| Ohms Accuracy | 0.9% + 1 || 5% + 2 |
| Diode test Range/resolution | 2.00 V / 0.001 V |
| Diode test Accuracy | 0.9% + 2 |
| Capacitance Range/resolution | 1000 nF / 1 nF10.00 μF / 0.01 μF100.0 μF / 0.1 μF9999 μF / 1 μF100 μF to 1000 μF || > 1000 μF |
| Capacitance Accuracy | 1.9% + 2 || 5% + 20% |
| Lo-Z capacitance Range | 1 nF to 500 μF |
| Lo-Z capacitance Accuracy | 10% + 2 typical |
| AC amps True RMS(45 Hz to 500Hz) Range/resolution | 6.000 A / 0.001 A10.00 A / 0.01 A |
| AC amps True RMS(45 Hz to 500Hz) Accuracy | 1.5% + 320 A overload for 30-seconds max |
| DC amps Range/resolution | 6.000 A / 0.001 A10.00 A / 0.01 A |
| DC amps Accuracy | 1.0% + 320 A overload for 30-seconds max |
| Hz (V or A input)2 Range/resolution | 99.99 Hz / 0.01 Hz999.9 Hz / 0.01 Hz9.999 kHz / 0.001 kHz50.00 kHz / 0.01 kHz |
| Hz (V or A input)2 Accuracy | 0.1% + 2 |