$1,203.09
Estimated price. Final price and availability are subject to confirmation. Contact our sales team for a current quote.
The Fluke 1587 FC Insulation Multimeter is designed for comprehensive electrical testing with wireless communication features. It allows users to monitor measurements remotely, share results instantly, and track asset conditions over time.
Key functionalities include insulation resistance testing, voltage, resistance, capacitance, temperature, and frequency measurements. It incorporates safety features such as live circuit detection and auto-discharge for user protection.
- Supports VFD low-pass filtering for accurate motor drive measurements
- Includes Fluke Connect memory storage for measurement data
- Wireless sharing and trending of measurement results via smartphone app
- Supports trend analysis for insulation degradation over time
- Includes test leads, remote probe, thermocouple, and hard case
Technical Specifications
| 600.0 mV Resolution | 0.1 mV || 0.1 mV |
| 600.0 mV | Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3) || Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts): ±(2% + 3) || Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3) || Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts): +(2% + 3), -(6% - 3) |
| 6.000 V Resolution | 0.001 V || 0.001 V |
| 6.000 V | Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3) || Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts): ±(2% + 3) || Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3) || Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts): +(2% + 3), -(6% - 3) |
| 60.00 V Resolution | 0.01 V || 0.01 V |
| 60.00 V | Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3) || Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts): ±(2% + 3) || Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3) || Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts): +(2% + 3), -(6% - 3) |
| 600.0 V Resolution | 0.1 V || 0.1 V |
| 600.0 V | Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3) || Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts): ±(2% + 3)¹ || Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(1% + 3) || Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts): +(2% + 3), -(6% - 3) || V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz: 100.0 V || V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz: - || DC Trigger Levels¹ to 20 kHz²: 12.0 V and 40.0 V |
| 1000 V Resolution | 1 V || 1 V |
| 1000 V | Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(2% + 3) || Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts): ±(2% + 3)¹ || Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts): ±(2% + 3) || Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts): +(2% + 3), -(6% - 3) |
| Range Resolution | Accuracy ±(% of Rdg + Counts) || Accuracy ±(% of Rdg + Counts) || Accuracy +(% of Rdg+Counts)¹ || Accuracy ±(% of Rdg+Counts) || Accuracy ±(% of Rdg+Counts) || Accuracy ±(% of Rdg+Counts)¹ |
| 6.000 V dc | 0.001 V: ±(0.09% + 2) |
| 60.00 V dc | 0.01 V: ±(0.09% + 2) |
| 600.0 V dc | 0.1 V: ±(0.09% + 2) |
| 1000 V dc | 1 V: ±(0.09% + 2) |
| Input impedance | 10 MΩ (nominal), <100 pF: 10 MΩ (nominal), <100 pF |
| Normal mode rejection ratio | >60 dB @ 50 Hz or 60 Hz: >60 dB @ 50 Hz or 60 Hz |
| Common mode rejection ratio | >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance): >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance) |
| 600.0 mVdc | 0.1 mV: ±(0.1% + 1) |
| Range | 400 mA: 400 mA || 60 mA: 60 mA || 400 mA: 400 mA || 60 mA: 60 mA |
| Resolution | 0.1 mA: 0.1 mA || 0.01 mA: 0.01 mA || 0.1 mA: 0.1 mA || 0.01 mA: 0.01 mA |
| Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹ | ±(1.5% + 2)¹ || ±(1.5% + 2)¹ |
| Burden voltage (Typical) | 2 mV/mA: 2 mV/mA || 2 mV/mA: 2 mV/mA || 2 mV/mA: 2 mV/mA || 2 mV/mA: 2 mV/mA |
| Accuracy ±(% of Rdg+Counts) ±(0.2% + 2) | ±(0.2% + 2) || ±(0.2% + 2) |
| Overload | 600 mA for 2 minutes maximum: 600 mA for 2 minutes maximum |
| Fuse protection for mA input | 0.44 mA, 1000 V, IR 10 kA: 0.44 mA, 1000 V, IR 10 kA || 0.44A, 1000 V, IR 10 kA: 0.44A, 1000 V, IR 10 kA |
| AC conversion | Inputs are ac-coupled and calibrated to the rms value of sine wave input: Inputs are ac-coupled and calibrated to the rms value of sine wave input |
| 600.0 Ω | 0.1 Ω: ±(0.9% + 2) |
| 6.000 kΩ | 0.001 kΩ: ±(0.9% + 2) |
| 60.00 kΩ | 0.01 kΩ: ±(0.9% + 2) |
| 600.0 kΩ | 0.1 KΩ: ±(0.9% + 2) |
| 6.000 MΩ | 0.001 MΩ: ±(0.9% + 2) |
| 50.0 MΩ ² | 0.01 MΩ: ±(1.5% + 3) |
| Overload protection | 1000 V rms or dc: 1000 V rms or dc || 1000 V rms: 1000 V rms |
| Open circuit test voltage | <8.0 V dc: <8.0 V dc |
Product Documents
Reviews: 0
There are no reviews for this product.
Questions: 0
No questions about this product.
Manual 1.12 MB
Manual 179.65 KB
Manual 1.77 MB
Manual 32.25 KB
1587 FC/1587/1577 | Safety sheet 197.21 KB

Spec Sheet