Model:
MPD-DS-FS-FDS-3P-4W-208V-2500A-EF-BM-N3R-TD
SKU:
MPD-DS-FS-FDS-3P-4W-208V-2500A-EF-BM-N3R-TD
Availability:
In Stock
Documents:
Spec Sheet
$52,706.25
Estimated price. Final price and availability are subject to confirmation. Contact our sales team for a current quote.
  0 reviews

Product Overview

Fused Disconnect Switch, 2500 Amp, 208V 3PH AC, 3-Pole 4-Wire, (3) Class L Time Delay Fuses, NEMA 3R is a product intended for professional commercial and industrial applications.

Key Specifications

  • Operation: The dead front disconnect switch features a locking door. The door provides access to a permanently attached operating handle, which is used for manually disconnecting or connecting power. A dead front cover protects operators from the fuses for safety. Operators can inspect the fuses through the dead front via a vented cover. Removing the dead front allows access to the fuses.
  • Time Delay: Time delay fuses are tripped once overcurrent heat builds up enough to melt the fuse element over a period of time. That period of time varies between different time delay fuses depending on the application. Time delay fuses decrease the chances of false tripping. During startup, many components require a large current for a very short amount of time. In other words, a time delay fuse disconnects the circuit only when the overcurrent persists in the line.
  • Fast Acting: Fast acting fuses are tripped immediately upon sensing an overcurrent or short circuit in the line. They are ideal for electronics, components, or systems that cannot withstand sudden changes in current. A fast acting fuse will not withstand a temporary overload such as one that occurs during the startup process.
  • Enclosure Design: The disconnect switch is protected by an 11GA sheet steel enclosure with ANSI 49 grey finish. A ventilated design promotes natural cooling and improves performance. The enclosure is NEMA 3R rated for protection against water, moisture and debris. This rating allows the fused disconnect to be used in indoor and outdoor areas.
  • Certification: This disconnect switch is NRTL listed to UL 891 dead front switchboards and NRTL listed for service equipment.
  • Mount: Operators can mount the service entrance disconnect on floors and flat surfaces.
  • Applications: This switchgear is suitable for indoor/outdoor use and applications including, but not limited to, construction sites, plant maintenance, plant turnarounds, hazardous location operations, shows, exhibits, and shipyard operations.

This item is grouped with Fused Disconnect Switches - Floor Mount Service Entrance Disconnects.

Before ordering: Verify ratings, dimensions, compatibility, and installation requirements before ordering.

Specifications

Applications
This switchgear is suitable for indoor/outdoor use and applications including, but not limited to, construction sites, plant maintenance, plant turnarounds, hazardous location operations, shows, exhibits, and shipyard operations.
Certification
This disconnect switch is NRTL listed to UL 891 dead front switchboards and NRTL listed for service equipment.
Enclosure Design
The disconnect switch is protected by an 11GA sheet steel enclosure with ANSI 49 grey finish. A ventilated design promotes natural cooling and improves performance. The enclosure is NEMA 3R rated for protection against water, moisture and debris. This rating allows the fused disconnect to be used in indoor and outdoor areas.
Fast Acting
Fast acting fuses are tripped immediately upon sensing an overcurrent or short circuit in the line. They are ideal for electronics, components, or systems that cannot withstand sudden changes in current. A fast acting fuse will not withstand a temporary overload such as one that occurs during the startup process.
Mount
Operators can mount the service entrance disconnect on floors and flat surfaces.
Operation
The dead front disconnect switch features a locking door. The door provides access to a permanently attached operating handle, which is used for manually disconnecting or connecting power. A dead front cover protects operators from the fuses for safety. Operators can inspect the fuses through the dead front via a vented cover. Removing the dead front allows access to the fuses.
Time Delay
Time delay fuses are tripped once overcurrent heat builds up enough to melt the fuse element over a period of time. That period of time varies between different time delay fuses depending on the application. Time delay fuses decrease the chances of false tripping. During startup, many components require a large current for a very short amount of time. In other words, a time delay fuse disconnects the circuit only when the overcurrent persists in the line.
Reviews: 0

There are no reviews for this product.

Questions: 0

No questions about this product.

Manual 4.88 MB
Spec Sheet 928.59 KB
Wiring Diagram 228.62 KB
Similar products