PRE-ENGINEERED ACCESS CONTROL
ACS-001A Published reference design

ACS-001A — Axis Networked Single-Door Access Control

IP-connected single-door package using an Axis controller, RFID reader, electric strike, supervised door contact and REX.

Standard Axis 1 door/lane RFID card Electric strike
SYSTEM ARCHITECTURE

How ACS-001A is built

Office / server room / controlled door · Axis

RFID cardUser presents credential
Credential ReaderReader / enrollment edge
Door ControllerCredential decision + I/O
Electric strikeControlled opening / lane
Door Contact + REXInputs back to controller
LAN / Access ManagementEvents, users, schedules, reporting
Access / Lock PowerController / reader / lock power
DESIGN INTENT

What this access-control design is meant to do

IP-connected single-door package using an Axis controller, RFID reader, electric strike, supervised door contact and REX.

The BOM below is product-based: controller, reader, lock/output hardware, REX, door position and access-power components are tied to live Safsale product cards. Treat this as a purchasing baseline and adjust it to the actual door hardware, credential policy, wire distances, lock current and site requirements.

Life-safety / door-hardware review required: final egress, fire-alarm release, fail-safe/fail-secure operation, accessibility, door hardware and local AHJ requirements must be verified for the actual opening. This page is not a permit drawing.
Controlled openings1 door / lane
Credential methodRFID card
Primary brandAxis
Lock / output typeElectric strike
Market tierStandard
Best fitOffice / server room / controlled door
Design classPre-engineered reference design; final door hardware, egress, fire/life-safety, accessibility and AHJ requirements are site-specific
ENGINEERING TOOLS

Calculate power, battery, cabling and capacity

These links open active planning calculators.

BILL OF MATERIALS

ACS-001A equipment list

Each row opens the real Safsale product card. Quantities are reference quantities for this design.

Required equipment total$2,523.55
Optional equipment shownRequest Quote
Request Project Quote
FAQ

ACS-001A questions

What is included in ACS-001A?

The reference BOM includes the access controller or standalone control device, credential readers where applicable, lock or controlled-output hardware, access power, request-to-exit and door-position components selected from live Safsale product cards.

Can I substitute a different reader or lock?

Often yes, but the interface and electrical requirements must match. Confirm Wiegand or OSDP compatibility, relay logic, lock voltage/current, fail-safe versus fail-secure operation, power budget and any manufacturer-specific requirements.

How do I size the access-control power supply and batteries?

Add the controller, readers, lock loads and auxiliary devices, account for continuous versus intermittent lock current, then add design headroom. Use the Safsale Access Power and Battery Backup calculators before selecting a supply or battery set.

Does this page guarantee code compliance?

No. Egress, fire alarm release, accessibility, door hardware and local AHJ requirements depend on the actual opening and occupancy. The reference design is a purchasing and planning baseline, not a permit drawing.

Can Safsale scale this to more doors?

Yes. Use the related designs or request a project-specific quote for a different door count, reader technology, lock type, backup duration, cable type or management platform.