PRE-ENGINEERED INTRUSION DETECTION
IDS-048N Published reference design

IDS-048N — NAPCO 48-Zone Facility Intrusion System

NAPCO GEM hybrid intrusion reference design for commercial openings, interior motion, glassbreak coverage and local audible notification.

ProNAPCO48 pointsHardwired / wireless hybrid
SYSTEM ARCHITECTURE

How IDS-048N is built

Facility / school wing · NAPCO

Hardwired + Wireless SensorsSupervised detection points
Intrusion Control PanelZone logic, partitions, events
Siren / CommunicatorLocal and remote signaling
Keypad / Remote ManagementArm, disarm, status, users
Standby Battery + Panel PowerStandby operation
DESIGN INTENT

What this intrusion design is meant to do

NAPCO GEM hybrid intrusion reference design for commercial openings, interior motion, glassbreak coverage and local audible notification.

The bill of materials is tied to real Safsale catalog products. Adjust zone count, detector placement, signaling, communication path, panel expansion, cable type and battery capacity for the actual property.

Reference design: false-alarm environment, central-station monitoring, local ordinances, police-response policy, insurance requirements and exact detector placement must be reviewed for the real site.
Reference points / zones48 detection points / zones
TechnologyHardwired / wireless hybrid
Primary platformNAPCO
Market tierPro
Best fitFacility / school wing
Design classPre-engineered intrusion reference design; final zone programming, signaling, monitoring, battery, code and insurance requirements are site-specific
ENGINEERING TOOLS

Plan zones, standby battery and cabling

BILL OF MATERIALS

IDS-048N equipment list

Each row opens the real Safsale product card.

Required equipment total$5,414.84
Optional equipment shownRequest Quote
Request Project Quote
FAQ

IDS-048N questions

What is included in IDS-048N?

The reference BOM combines a compatible intrusion control platform with the detector mix, opening protection, audible signaling, cabling or wireless accessories and standby battery items shown on the page.

How many zones should the panel have?

Count every separately supervised detection input, then add spare capacity for future devices and partitioning. Use the Intrusion Zone Planner to establish a first-pass panel capacity.

How should alarm battery backup be sized?

Battery capacity depends on standby current, required standby hours and any alarm/high-load period. Use the Battery Backup Calculator with actual panel, keypad, communicator and auxiliary-device current values.

Can wired and wireless detectors be mixed?

On platforms that support hybrid expansion, yes. Verify receiver compatibility, supported frequencies/encryption, zone capacity and required expansion modules for the selected panel.

Is this a final alarm-system design?

No. Monitoring, signaling, police-response policy, insurance requirements, local codes, false-alarm rules and exact detector placement must be verified for the actual site.