The RDL ST-VOX1 Voice-Activated Relay is designed for switching operations controlled by voice signals from a microphone or line level source.
The RDL ST-VOX1 Voice-Activated Relay is designed for switching operations controlled by voice signals from a microphone or line level source. This relay features adjustable input sensitivity for both microphone and line inputs, with specific ranges for each. The control output is an open-collector signal capable of driving indicators or slave LCR devices. It includes double-pole, double-throw relay contacts, with switching power specifications of 60 W and 125 VA maximum.
The relay can handle up to 2 A of switching current and 3 A of carrying current. Additional features include an audio threshold LED indicator, retrigger delay of 50 ms, and adjustable release delay times for both relay contacts and slave outputs. The product requires a power supply of 24 to 33 VDC at 50mA, with a maximum load of 20mA at the slave output.
- Input Impedance: Mic: 5 k ohms Unbalanced Line: 200 k ohms Unbalanced
- Input Sensitivity: Mic: -75 to -25 dBu (Adjustable) Line: -45 to -15 dBu (Adjustable)
- Control Output: Open-Collector @ 50mA, Suitable to Drive Indicators or Slave LCR
- Relay Contacts: Double-Pole, Double-Throw
- Switching Power: 60 W, 125 VA (Max)
Specifications
There are no reviews for this product.
No questions about this product.