The Schneider Electric ATV950 is a high-performance variable speed drive suitable for industrial motor control. It offers precise speed and torque regulation for synchronous, asynchronous, or reluctance motors, with a power rating of 30kW and a voltage range of 380 to 480V.
Constructed with a sheet steel housing, it supports various communication protocols including EtherNet/IP, Modbus TCP, and Modbus serial. The drive conforms to multiple standards such as UL 508C, IEC 61800-3, IEC 61508, and others, ensuring reliable operation in demanding environments.
- Power rating: 30 kW (40 HP)
- Voltage: 380 to 480 V
- Enclosure: IP55, UL type 12
- Communication ports: 2 RJ45, 1 RJ45
- Maximum switching current: relay output R1 inductive, 2 A at 30 V DC; relay outputs R2, R3 resistive, 5 A at 30 V DC
- Maximum associated fuse rating: 100 A
- Operating position: Vertical +/- 10 degrees
- Removable battery: Yes
- Design: Enclosed, wall mount
This drive is suitable for process control in industrial settings, with a service life expectancy of approximately 10 years and support for advanced safety functions such as safe torque off and safe stop features.
Technical Specifications
| Communications & Management Attributes - Communication Port Protocol | EtherNet/IP, Modbus TCP, Modbus serial |
| Conformance Attributes - Product Certifications | DNV-GL, TÜV, ABS, ATEX INERIS, CSA, UL, Bureau Veritas |
| Conformance Attributes - Standards | UL 508C, IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1 |
| Complementary Attributes - Maximum Switching Current | relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC, relay output R2, R3 resistive, cos phi = 1 5 A 30 V DC, relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC, relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC, relay output R1 resistive, cos phi = 1 3 A 250 V AC, relay output R1 resistive, cos phi = 1 3 A 30 V DC, relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC, relay output R2, R3 resistive, cos phi = 1 5 A 250 V AC |
| Complementary Attributes - Maximum Thdi | <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12, <48 % from 80...100 % of load IEC 61000-3-12 |
| Complementary Attributes - Maximum Transient Current | 73.8 A 60 s normal duty), 69.5 A 60 s heavy duty) |
| Complementary Attributes - Ue Rated Operational Voltage | 380...480 V 30.0 kW normal duty, 380...480 V 22.0 kW heavy duty |
| Complementary Attributes - Us Rated Supply Voltage | 380...480 V, 380...480 V - 15...10 % |
| Complementary Attributes - Brake Chopper Integrated | true |
| Complementary Attributes - Maximum Associated Fuse Rating | 100.0 A |
| Complementary Attributes - Maximum Input Current Per Phase | 53.3 A |
| Complementary Attributes - Maximum Output Frequency | 599 Hz |
| Complementary Attributes - Maximum Output Voltage | 480.0 V |
| Complementary Attributes - Minimum Switching Current | relay output R1, R2, R3 5 mA 24 V DC |
| Complementary Attributes - Maximum Acceleration Under Shock Impact During Operation | 150 m/s² at 11 ms |
| Complementary Attributes - Maximum Acceleration Under Shock Load During Storage | 150 m/s² at 11 ms |
| Complementary Attributes - Maximum Acceleration Under Shock Load During Transport | 150 m/s² at 11 ms |
| Complementary Attributes - Maximum Acceleration Under Vibrational Stress During Operation | 10 m/s² at 13...200 Hz |
| Complementary Attributes - Maximum Acceleration Under Vibratory Load During Storage | 10 m/s² at 13...200 Hz |
| Complementary Attributes - Maximum Acceleration Under Vibratory Load During Transport | 10 m/s² at 13...200 Hz |
| Complementary Attributes - Maximum Deflection Under Vibratory Load During Operation | 1.5 mm at 2...13 Hz |
| Complementary Attributes - Maximum Deflection Under Vibratory Load During Storage | 1.5 mm at 2...13 Hz |
| Complementary Attributes - Maximum Deflection Under Vibratory Load During Transport | 1.5 mm at 2...13 Hz |
| Product Contributes To Saved And Avoided Emissions | YES_SSI2, Yes |
| Persona Type Ids | EU, OM, OM8, SI |
| Persona Type Names | End User, Original Equipment Manufacturer, OEM - Control Panelbuilder, System Integrator |
| Apparent Power | 29.8 kVA 480 V heavy duty), 38.2 kVA 480 V normal duty) |
| Asynchronous Motor Control Profile | variable torque standard, constant torque standard, optimized torque mode |
| Connector Type | 2 RJ45, 1 RJ45 |
| Data Format | 8 bits, configurable odd, even or no parity Modbus serial, 8 bits, configurable odd, even or no parity |
| Electromagnetic Compatibility | electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2, radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4, 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5, conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
| Emc Filter | integrated, with EMC plate option |
| Encoder Protocol | 1 Vpp, EnDat 2.2, resolver, RS 422, SSI 24V, SSI 5V, TTL/HTL |
| Line Current | 53.3 A 380 V normal duty), 40.5 A 380 V heavy duty), 45.9 A 480 V normal duty), 35.8 A 480 V heavy duty) |
| Linearity Error | AI1, AI2, AI3 +/- 0.15 % of maximum value analog input, AQ1, AQ2 +/- 0.2 % analog output |