The Square D TeSys T motor management controller is designed for equipment monitoring and control applications. It features DeviceNet communication protocol, allowing seamless integration into industrial networks. The device supports six inputs and three relay outputs, with a rated load current of 1.35 to 27A and operating voltage of 100 to 240VAC.
- DeviceNet communication port protocol
- Ui rated insulation voltage of 690 V according to EN/IEC 60947-1, CSA C22.2 No 14, and UL 508
- Impulse withstand voltage of 4 kV supply, inputs, and outputs
- Maximum operating frequency of 2 Hz and rate of 1800 cycles per hour
- Short circuit withstand capacity of 100 kA conforming to EN/IEC 60947-4-1
- Rated supply voltage of 100 to 240 V AC at 50/60 Hz
- Mechanical robustness tested for vibrations and shocks
- Protection class IP20
- Operational ambient temperature range from -20°C to 60°C
Technical Specifications
| Communications & Management Attributes - Communication Port Protocol | DeviceNet |
| Complementary Attributes - Ui Rated Insulation Voltage | 690 V EN/IEC 60947-1, 690 V CSA C22.2 No 14, 690 V UL 508 |
| Complementary Attributes - Uimp Rated Impulse Withstand Voltage | 4 kV supply, inputs and outputs EN/IEC 60947-4-1, 6 kV current or voltage measurement circuit EN/IEC 60947-4-1, 0.8 kV communication circuit EN/IEC 60947-4-1 |
| Complementary Attributes - Maximum Operating Frequency | 2 Hz |
| Complementary Attributes - Maximum Operating Rate | 1800 cyc/h |
| Complementary Attributes - Short Circuit Withstand | 100 kA conforming to EN/IEC 60947-4-1 |
| Complementary Attributes - Us Rated Supply Voltage | 100...240 V AC 50/60 Hz |
| Persona Type Ids | EU, LC, OM, OM8, PB |
| Persona Type Names | End User, Contractor, Original Equipment Manufacturer, OEM - Control Panelbuilder, Panel Builder |
| Market Segmentation Id | COMMERCIAL, INDUSTRIAL |
| Market Segmentation | Commercial, Industrial |
| Associated Fuse Rating | 4 A gG output, 0.5 A gG control circuit |
| Contacts Type And Composition | 1 NO + 1 NC fault signal, 3 NO |
| Electromagnetic Compatibility | control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5, electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2, communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5, relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5, relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5, control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5, radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3, fast transients immunity test (other circuits), leve |
| Fire Resistance | 650 °C EN/IEC 60695-2-12, 960 °C UL 94 |
| Load Current | 5 A 250 V AC logic output, 5 A 30 V DC logic output |
| Measurement Accuracy | +/- 30 min/year internal clock, +/- 30 min/year internal clock, 5...15 % earth fault current internal measurement, 1 % voltage 100...830 V), 3 % power factor, 5 % earth fault current external measurement, +/- 30 min/year internal clock, +/- 30 min/year internal clock, 0,02 Temperature, 1 % current, 5 % active and reactive power |
| Mechanical Robustness | vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6, vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6, shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27 |
| Metering Type | imbalance current, temperature, earth-fault current, average current Iavg, phase current I1, I2, I3 RMS |
| Network And Machine Diagnosis Type | trip history information, trip context information, running hours counter/operating time, remaining operating time before overload tripping, fault recording, waiting time after overload tripping, starting current and time, phase fault and earth fault trip counters, event recording, motor control command recording |
| Permissible Power | 480 VA AC-15), Ie = 2 A, 500000 cycles output), 30 W DC-13), Ie = 1.25 A, 500000 cycles output) |
| Protection Type | thermal overload protection, power factor variation, phase failure, overload (long time), reverse polarity protection, earth-leakage protection, thermal protection, locked rotor, load fluctuation, overload, phase unbalance |
| Protective Treatment | 12 x 24 hour cycles EN/IEC 60068-2-30, 48 h EN/IEC 60070-2-11, TH EN/IEC 60068 |
| Connections Terminals | control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible without cable end, control circuit connector 2 0.2-1.5 mm² AWG 24...AWG 14)flexible without cable end, control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)solid without cable end, control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible with cable end, control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)flexible without cable end, control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)solid without cable end, control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)flexible with cable end, control circuit connector |
| Carbon Footprint Of The Distribution Phase A4 | 0.0678292917219235, 0.1 kg CO2 eq. |
| Carbon Footprint Of The End Of Life Phase C1 To C4 | 1.008308292001472, 1 kg CO2 eq. |
| Carbon Footprint Of The Installation Phase A5 | 0.2 kg CO2 eq., 0.20159579532093852 |
| Carbon Footprint Of The Manufacturing Phase A1 To A3 | 18 kg CO2 eq., 18.33296993254577 |
| Carbon Footprint Of The Use Phase B2 B3 B4 B6 | 11 kg CO2 eq., 11.22355161504505 |
| Certificate Agency | LROS (Lloyds register of shipping), NOM, GL, C-tick, ATEX, KERI, DNV, BV, RINA, UL, RMRoS, EAC, CCC, CSA, ABS |
| Local Data Status | Publishable |
| Local Publishable Date | 2026-04-10 |
| Return Indicator | Y |
| Stocking Flag | N |
| Stock Policy | 2 |