Model:
IND-HVAC-DTS-UVC-R1-SS-9W-2L-24V-5CSKU:
IND-HVAC-DTS-UVC-R1-SS-9W-2L-24V-5CAvailability:
In StockDocuments:
Spec Sheet
$907.35
Estimated price. Final price and availability are subject to confirmation. Contact our sales team for a current quote.
Product Overview
UV Low Profile Split Disinfection Fixture - UV-C - Destroys Airborne Bacteria & Viruses - 24V AC - 4.8W UV Output - L-Brackets for Mounting is a product intended for professional commercial and industrial applications.
Key Specifications
- Operation: This UV ductless AC disinfection system projects ultraviolet rays inside the AC unit it is mounted in. The air flowing through the unit that passes through the UV rays is then sanitized. Bacteria and viruses present in the air that passes through the UV rays produced by the fixture are destroyed. The air moving through the AC unit is constantly being purified as it flows through the UV rays being produced by the fixture.
- Wiring: The IND-HVAC-DTS-UVC-R1-SS-9W-2L-24V-5C is comprised of a ballast box and two compact fluorescent UVC bulbs. Each bulb is connected to the ballast box by a 5` 16/3 SOOW cord to allow for flexible mounting depending on the particular ductless AC unit it will be mounted in. The ballast is equipped with a 5` 16/3 SOOW cord that is terminated in flying leads and must be hardwired.
- Mounting: The IND-HVAC-DTS-UVC-R1-SS-9W-2L-24V-5C is designed to be mounted inside a mini-split ductless air conditioning unit. Each of the UVC bulbs is outfitted with a L-bracket for flat surface mounting inside the AC unit. The accompanying ballast box can also be surface mounted on the interior of the unit.
- Note on Environment: Sunlight and visible light fixtures do not impact the effectiveness of the disinfecting on this UVC sanitation product. Metal halide, high pressure sodium, fluorescent, and LED light fixtures can be left on. The UV radiation emitted from this product is not disrupted by any type of lighting in the environment. Put simply, NO it DOES NOT need to be dark in the area you plan to disinfect. The UV radiation is harmful to the eyes and skin, and that is why you should not be in the area while it is in operation. Please see user manual for additional safety information.
- Applications: This ultraviolet UV mini=split ductless AC disinfection system can be used to continuously disinfect air of mold, allergens, airborne bacteria, viruses, and germs. The IND-HVAC-DTS-UVC-R1-SS-9W-2L-24V-5C is ideal for use in restaurants, hospitals, clinics, laboratories, nursing homes, schools, food processing facilities, office buildings, conference rooms, universities, clean rooms, and many more.
This item is grouped with High Bay UV Sanitation Lighting.
Before ordering: Verify ratings, dimensions, compatibility, and installation requirements before ordering.
Specifications
Applications
This ultraviolet UV mini=split ductless AC disinfection system can be used to continuously disinfect air of mold, allergens, airborne bacteria, viruses, and germs. The IND-HVAC-DTS-UVC-R1-SS-9W-2L-24V-5C is ideal for use in restaurants, hospitals, clinics, laboratories, nursing homes, schools, food processing facilities, office buildings, conference rooms, universities, clean rooms, and many more.
Mounting
The IND-HVAC-DTS-UVC-R1-SS-9W-2L-24V-5C is designed to be mounted inside a mini-split ductless air conditioning unit. Each of the UVC bulbs is outfitted with a L-bracket for flat surface mounting inside the AC unit. The accompanying ballast box can also be surface mounted on the interior of the unit.
Note on Environment
Sunlight and visible light fixtures do not impact the effectiveness of the disinfecting on this UVC sanitation product. Metal halide, high pressure sodium, fluorescent, and LED light fixtures can be left on. The UV radiation emitted from this product is not disrupted by any type of lighting in the environment. Put simply, NO it DOES NOT need to be dark in the area you plan to disinfect. The UV radiation is harmful to the eyes and skin, and that is why you should not be in the area while it is in operation. Please see user manual for additional safety information.
Operation
This UV ductless AC disinfection system projects ultraviolet rays inside the AC unit it is mounted in. The air flowing through the unit that passes through the UV rays is then sanitized. Bacteria and viruses present in the air that passes through the UV rays produced by the fixture are destroyed. The air moving through the AC unit is constantly being purified as it flows through the UV rays being produced by the fixture.
Technical
Wiring
The IND-HVAC-DTS-UVC-R1-SS-9W-2L-24V-5C is comprised of a ballast box and two compact fluorescent UVC bulbs. Each bulb is connected to the ballast box by a 5` 16/3 SOOW cord to allow for flexible mounting depending on the particular ductless AC unit it will be mounted in. The ballast is equipped with a 5` 16/3 SOOW cord that is terminated in flying leads and must be hardwired.
Reviews: 0
There are no reviews for this product.
Questions: 0
No questions about this product.
Spec Sheet 94.74 KB
Lighting Facts 1.41 MB
Eye Safety 1.02 MB
Certificate 4 327.63 KB
Lighting Facts 1.41 MB
Shipping Time Map 424.5 KB