The Verkada SV25 Environmental Sensor (128GB) is designed to monitor various environmental factors.
The Verkada SV25 Environmental Sensor (128GB) is designed to monitor various environmental factors. It includes 15 onboard sensors with programmable alerts for each measurement, providing notifications in less than one second. The sensor offers accurate readings with a typical accuracy of ±0.9°F / ±0.5°C for temperature and ±3% at 25°C for humidity. Additional sensors include CO2, PM4, TVOC index, motion, vape index, noise, CO, barometric pressure, and formaldehyde sensors.
The device supports wireless connectivity and operates on PoE power source. It has a power consumption of 4 W and includes mounting hardware such as wall mount, single-gang junction box, European junction box, 3.5" round junction box, and 4" round junction box. The sensor is certified for FCC Part 15B Class B, ICES-003 Class B, and NDAA. It operates within a temperature range of 23 to 113°F / -5 to 45°C at 0 to 95% humidity.
- Compatibility: Verkada Command
- Sensor: Temperature Operating Range: 23 to 113°F / -5 to 45°C Typical Accuracy: ±0.9°F / ±0.5°C Max ±1.8°F / ±1°C Humidity Operating Range: 0-95% (Non-Condensing) Typical Accuracy: ±3% @ 25°C CO 2 Sensor: Photoacoustic Range: 0-40,000 ppm Typical Accuracy 400-1000 ppm ±75 ppm 1001-2000 ppm ±40 ppm + 5% of Reading PM 2.5 Sensor: Laser Scattering Optical Sensor Range: 0 - 1000 Microgram / m3 Typical Accuracy: 0 - 100 Micrograms / m3: ±25 Micrograms / m3 + 5% m.v
- Sensor: PM 4 Sensor: Laser Scattering Optical Sensor Range: 0 - 1000 Micrograms / m3 Typical Accuracy: 0 - 100 Micrograms / m3: ±25 Micrograms / m3 100 - 1000 Micrograms / m3: ±25% m.v. TVOC Index Sensor MOX Range: 0 - 500 Motion Sensor: Passive Infrared Sensor FoV: 120° Air Quality Index Sensor: U.S. Air Quality Index Derived from Multiple Sensors Range: 0 - 500 PM 10 Sensor: Laser Scattering Optical Sensor Range: 0 - 1000 Micrograms / m3 Typical Accuracy: 0 - 100 Microgram / m3: ±25 Micrograms / m3 10
- Sensor: Vape Index Sensor: Proprietary Formula Derived from Multiple Sensors Range: 0 - 100 Noise Sensor: MEMS Microphone Range: 20 - 120 dB SPL (A-Weighted) Typical Accuracy: ±5 dB
- Sensor: CO Sensor: Electrochemical Range: 0 - 1000 ppm Barometric Pressure Sensor: Piezoresistive Range: 300 - 1250 hPa Typical Accuracy: ±50 Pa Formaldehyde Sensor: Electrochemical Range: 0 - 5000 ppb Accuracy: ±20 ppb or ±20% m.v., Whichever Is Larger Audio Recording Sensor: Omnidirectional Microphone Light Sensor: CMOS Range: 0 - 7000 lux Typical Accuracy: ±(6+5% Reading) lux Audio Retention From 90 days to 365 days
Specifications
There are no reviews for this product.
No questions about this product.